Saved in:
Bibliographic Details
Main Author: White, Sebastian
Format: Preprint
Published: 2024
Subjects:
Online Access:https://arxiv.org/abs/2405.08191
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866914795657101312
author White, Sebastian
author_facet White, Sebastian
contents In preparation for HL-LHC operation a number of new detector systems are being constructed with timing precision on physics objects of <50 picoseconds. These time stamps will reduce the level of pileup induced backgrounds in this LHC phase where the number of interactions per crossing will reach of order 100-200. In the case of CMS, three new systems have initially to be corrected for the usual amplitude walk resulting from the effect of variations in signal size on leading edge timing. In these systems the resulting timing spread (ie walk) ranges from one to four nanoseconds. In the following note we advocate approaching this initial calibration for walk as a calculable correction given early calibration during commissioning -- rather than depending on special collider data to perform the calibration. We derive a simple analytic expression for the walk correction and confirm its effectiveness with lab data.
format Preprint
id arxiv_https___arxiv_org_abs_2405_08191
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle Initial Calibration of Large Timing Arrays for the LHC
White, Sebastian
High Energy Physics - Experiment
Instrumentation and Detectors
In preparation for HL-LHC operation a number of new detector systems are being constructed with timing precision on physics objects of <50 picoseconds. These time stamps will reduce the level of pileup induced backgrounds in this LHC phase where the number of interactions per crossing will reach of order 100-200. In the case of CMS, three new systems have initially to be corrected for the usual amplitude walk resulting from the effect of variations in signal size on leading edge timing. In these systems the resulting timing spread (ie walk) ranges from one to four nanoseconds. In the following note we advocate approaching this initial calibration for walk as a calculable correction given early calibration during commissioning -- rather than depending on special collider data to perform the calibration. We derive a simple analytic expression for the walk correction and confirm its effectiveness with lab data.
title Initial Calibration of Large Timing Arrays for the LHC
topic High Energy Physics - Experiment
Instrumentation and Detectors
url https://arxiv.org/abs/2405.08191