Binding energy referencing in X-ray photoelectron spectroscopy: expanded data set confirms that adventitious carbon aligns to the vacuum level

Fuente: arXiv
Gespeichert in:
Bibliographische Detailangaben
1. Verfasser: Greczynski, Grzegorz
Format: Preprint
Veröffentlicht: 2024
Schlagworte:
Online-Zugang:
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
_version_ 1866914879068176384
author Greczynski, Grzegorz
author_facet Greczynski, Grzegorz
contents The correct referencing of the binding energy (BE) scale is essential for the accuracy of chemical analysis by x-ray photoelectron spectroscopy. The C 1s C C/C-H peak from adventitious carbon (AdC), most commonly used for that purpose, was previously shown to shift by several eVs following changes in the sample work function, thus indicating that AdC aligns to the sample vacuum level (VL). Here, results from a much larger sample set are presented including 360 specimens of thin-film samples comprising metals, nitrides, carbides, borides, oxides, carbonitrides, and oxynitrides. Irrespective of the material system the C 1s peak of AdC is found to follow changes in the sample work function fully confirming previous results. Several observations exclude differential charging as plausible explanation. All experimental evidence points instead to the VL alignment at the AdC/sample interface as the source of shifts. Should the C 1s peak of AdC be used for spectra referencing the measurement of sample work function is necessary, irrespective of whether samples are measured grounded or insulated from the spectrometer.
format Preprint
id arxiv_https___arxiv_org_abs_2405_10919
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle Binding energy referencing in X-ray photoelectron spectroscopy: expanded data set confirms that adventitious carbon aligns to the vacuum level
Greczynski, Grzegorz
Materials Science
Chemical Physics
The correct referencing of the binding energy (BE) scale is essential for the accuracy of chemical analysis by x-ray photoelectron spectroscopy. The C 1s C C/C-H peak from adventitious carbon (AdC), most commonly used for that purpose, was previously shown to shift by several eVs following changes in the sample work function, thus indicating that AdC aligns to the sample vacuum level (VL). Here, results from a much larger sample set are presented including 360 specimens of thin-film samples comprising metals, nitrides, carbides, borides, oxides, carbonitrides, and oxynitrides. Irrespective of the material system the C 1s peak of AdC is found to follow changes in the sample work function fully confirming previous results. Several observations exclude differential charging as plausible explanation. All experimental evidence points instead to the VL alignment at the AdC/sample interface as the source of shifts. Should the C 1s peak of AdC be used for spectra referencing the measurement of sample work function is necessary, irrespective of whether samples are measured grounded or insulated from the spectrometer.
title Binding energy referencing in X-ray photoelectron spectroscopy: expanded data set confirms that adventitious carbon aligns to the vacuum level
topic Materials Science
Chemical Physics
url https://arxiv.org/abs/2405.10919