Kaonic lead feasibility measurement at DAΦNE to solve the charged kaon mass discrepancy

Fuente: arXiv
Salvato in:
Dettagli Bibliografici
Autori principali: Bosnar, D., Abbene, L., Amsler, C., Artibani, F., Bazzi, M., Bragadireanu, M., Buttacavoli, A., Cargnelli, M., Carminati, M., Clozza, A., Clozza, F., Deda, G., De Paolis, L., Del Grande, R., Dulski, K., Fabbietti, L., Fiorini, C., Friščić, I., Guaraldo, C., Iliescu, M., Iwasaki, M., Khreptak, A., Makek, M., Manti, S., Marton, J., Moskal, P., Napolitano, F., Niedźwiecki, S., Ohnishi, H., Piscicchia, K., Scordo, A., Sgaramella, F., Sirghi, D., Sirghi, F., Skurzok, M., Silarski, M., Spallone, A., Toho, K., Tüchler, M., Doce, O. Vasquez, Zmeskal, J., Curceanu, C.
Natura: Preprint
Pubblicazione: 2024
Soggetti:
Accesso online:
Tags: Aggiungi Tag
Nessun Tag, puoi essere il primo ad aggiungerne!!
_version_ 1866914804063535104
author Bosnar, D.
Abbene, L.
Amsler, C.
Artibani, F.
Bazzi, M.
Bragadireanu, M.
Buttacavoli, A.
Cargnelli, M.
Carminati, M.
Clozza, A.
Clozza, F.
Deda, G.
De Paolis, L.
Del Grande, R.
Dulski, K.
Fabbietti, L.
Fiorini, C.
Friščić, I.
Guaraldo, C.
Iliescu, M.
Iwasaki, M.
Khreptak, A.
Makek, M.
Manti, S.
Marton, J.
Moskal, P.
Napolitano, F.
Niedźwiecki, S.
Ohnishi, H.
Piscicchia, K.
Scordo, A.
Sgaramella, F.
Sirghi, D.
Sirghi, F.
Skurzok, M.
Silarski, M.
Spallone, A.
Toho, K.
Tüchler, M.
Doce, O. Vasquez
Zmeskal, J.
Curceanu, C.
author_facet Bosnar, D.
Abbene, L.
Amsler, C.
Artibani, F.
Bazzi, M.
Bragadireanu, M.
Buttacavoli, A.
Cargnelli, M.
Carminati, M.
Clozza, A.
Clozza, F.
Deda, G.
De Paolis, L.
Del Grande, R.
Dulski, K.
Fabbietti, L.
Fiorini, C.
Friščić, I.
Guaraldo, C.
Iliescu, M.
Iwasaki, M.
Khreptak, A.
Makek, M.
Manti, S.
Marton, J.
Moskal, P.
Napolitano, F.
Niedźwiecki, S.
Ohnishi, H.
Piscicchia, K.
Scordo, A.
Sgaramella, F.
Sirghi, D.
Sirghi, F.
Skurzok, M.
Silarski, M.
Spallone, A.
Toho, K.
Tüchler, M.
Doce, O. Vasquez
Zmeskal, J.
Curceanu, C.
contents An HPGe detector equipped with a transistor reset preamplifier and readout with a CAEN DT5781 fast pulse digitizer was employed in the measurement of X-rays from kaonic lead at the DA$Φ$NE $e^+e^-$ collider at the Laboratori Nazionali di Frascati of INFN. A thin scintillator in front of a lead target was used to select kaons impinging on it and to form the trigger for the HPGe detector. We present the results of the kaonic lead feasibility measurement, where we show that the resolution of the HPGe detector in regular beam conditions remains the same as that without the beam and that a satisfactory background reduction can be achieved. This measurement serves as a test bed for future dedicated kaonic X-rays measurements for the more precise determination of the charged kaon mass.
format Preprint
id arxiv_https___arxiv_org_abs_2405_12942
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle Kaonic lead feasibility measurement at DAΦNE to solve the charged kaon mass discrepancy
Bosnar, D.
Abbene, L.
Amsler, C.
Artibani, F.
Bazzi, M.
Bragadireanu, M.
Buttacavoli, A.
Cargnelli, M.
Carminati, M.
Clozza, A.
Clozza, F.
Deda, G.
De Paolis, L.
Del Grande, R.
Dulski, K.
Fabbietti, L.
Fiorini, C.
Friščić, I.
Guaraldo, C.
Iliescu, M.
Iwasaki, M.
Khreptak, A.
Makek, M.
Manti, S.
Marton, J.
Moskal, P.
Napolitano, F.
Niedźwiecki, S.
Ohnishi, H.
Piscicchia, K.
Scordo, A.
Sgaramella, F.
Sirghi, D.
Sirghi, F.
Skurzok, M.
Silarski, M.
Spallone, A.
Toho, K.
Tüchler, M.
Doce, O. Vasquez
Zmeskal, J.
Curceanu, C.
Instrumentation and Detectors
Nuclear Experiment
An HPGe detector equipped with a transistor reset preamplifier and readout with a CAEN DT5781 fast pulse digitizer was employed in the measurement of X-rays from kaonic lead at the DA$Φ$NE $e^+e^-$ collider at the Laboratori Nazionali di Frascati of INFN. A thin scintillator in front of a lead target was used to select kaons impinging on it and to form the trigger for the HPGe detector. We present the results of the kaonic lead feasibility measurement, where we show that the resolution of the HPGe detector in regular beam conditions remains the same as that without the beam and that a satisfactory background reduction can be achieved. This measurement serves as a test bed for future dedicated kaonic X-rays measurements for the more precise determination of the charged kaon mass.
title Kaonic lead feasibility measurement at DAΦNE to solve the charged kaon mass discrepancy
topic Instrumentation and Detectors
Nuclear Experiment
url https://arxiv.org/abs/2405.12942