A study on the adequacy of common IQA measures for medical images

Fuente: arXiv
Saved in:
Bibliographic Details
Main Authors: Breger, Anna, Karner, Clemens, Selby, Ian, Gröhl, Janek, Dittmer, Sören, Lilley, Edward, Babar, Judith, Beckford, Jake, Else, Thomas R, Sadler, Timothy J, Shahipasand, Shahab, Thavakumar, Arthikkaa, Roberts, Michael, Schönlieb, Carola-Bibiane
Format: Preprint
Published: 2024
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866915232809484288
author Breger, Anna
Karner, Clemens
Selby, Ian
Gröhl, Janek
Dittmer, Sören
Lilley, Edward
Babar, Judith
Beckford, Jake
Else, Thomas R
Sadler, Timothy J
Shahipasand, Shahab
Thavakumar, Arthikkaa
Roberts, Michael
Schönlieb, Carola-Bibiane
author_facet Breger, Anna
Karner, Clemens
Selby, Ian
Gröhl, Janek
Dittmer, Sören
Lilley, Edward
Babar, Judith
Beckford, Jake
Else, Thomas R
Sadler, Timothy J
Shahipasand, Shahab
Thavakumar, Arthikkaa
Roberts, Michael
Schönlieb, Carola-Bibiane
contents Image quality assessment (IQA) is standard practice in the development stage of novel machine learning algorithms that operate on images. The most commonly used IQA measures have been developed and tested for natural images, but not in the medical setting. Reported inconsistencies arising in medical images are not surprising, as they have different properties than natural images. In this study, we test the applicability of common IQA measures for medical image data by comparing their assessment to manually rated chest X-ray (5 experts) and photoacoustic image data (2 experts). Moreover, we include supplementary studies on grayscale natural images and accelerated brain MRI data. The results of all experiments show a similar outcome in line with previous findings for medical images: PSNR and SSIM in the default setting are in the lower range of the result list and HaarPSI outperforms the other tested measures in the overall performance. Also among the top performers in our experiments are the full reference measures FSIM, LPIPS and MS-SSIM. Generally, the results on natural images yield considerably higher correlations, suggesting that additional employment of tailored IQA measures for medical imaging algorithms is needed.
format Preprint
id arxiv_https___arxiv_org_abs_2405_19224
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle A study on the adequacy of common IQA measures for medical images
Breger, Anna
Karner, Clemens
Selby, Ian
Gröhl, Janek
Dittmer, Sören
Lilley, Edward
Babar, Judith
Beckford, Jake
Else, Thomas R
Sadler, Timothy J
Shahipasand, Shahab
Thavakumar, Arthikkaa
Roberts, Michael
Schönlieb, Carola-Bibiane
Image and Video Processing
Computer Vision and Pattern Recognition
Image quality assessment (IQA) is standard practice in the development stage of novel machine learning algorithms that operate on images. The most commonly used IQA measures have been developed and tested for natural images, but not in the medical setting. Reported inconsistencies arising in medical images are not surprising, as they have different properties than natural images. In this study, we test the applicability of common IQA measures for medical image data by comparing their assessment to manually rated chest X-ray (5 experts) and photoacoustic image data (2 experts). Moreover, we include supplementary studies on grayscale natural images and accelerated brain MRI data. The results of all experiments show a similar outcome in line with previous findings for medical images: PSNR and SSIM in the default setting are in the lower range of the result list and HaarPSI outperforms the other tested measures in the overall performance. Also among the top performers in our experiments are the full reference measures FSIM, LPIPS and MS-SSIM. Generally, the results on natural images yield considerably higher correlations, suggesting that additional employment of tailored IQA measures for medical imaging algorithms is needed.
title A study on the adequacy of common IQA measures for medical images
topic Image and Video Processing
Computer Vision and Pattern Recognition
url https://arxiv.org/abs/2405.19224