Kinetic Parameters analysis of GdAlO$_3$ based on thermoluminescent phenomenon

Fuente: arXiv
Salvato in:
Dettagli Bibliografici
Autori principali: Nolasco-Altamirano, D., Romero-Nuñez, C. S., Alonso-Sotolongoza, A., Benavente, J. F., García-Salcedo, R., García-Garduño, O. A., Zarate-Medina, J., Correcher, V., Montalvo, T. Rivera
Natura: Preprint
Pubblicazione: 2024
Soggetti:
Accesso online:
Tags: Aggiungi Tag
Nessun Tag, puoi essere il primo ad aggiungerne!!
_version_ 1866909397952757760
author Nolasco-Altamirano, D.
Romero-Nuñez, C. S.
Alonso-Sotolongoza, A.
Benavente, J. F.
García-Salcedo, R.
García-Garduño, O. A.
Zarate-Medina, J.
Correcher, V.
Montalvo, T. Rivera
author_facet Nolasco-Altamirano, D.
Romero-Nuñez, C. S.
Alonso-Sotolongoza, A.
Benavente, J. F.
García-Salcedo, R.
García-Garduño, O. A.
Zarate-Medina, J.
Correcher, V.
Montalvo, T. Rivera
contents {We herein report on the calculation of thermoluminescence (TL) kinetic parameters determined from the TL emission of synthetic GdAlO3 (GAO) phosphors prepared by the co-precipitation method. The sample, characterized by means of X-ray diffraction with an orthorhombic phase structure (space group Pnma (62), shows complex glow curves consisting of at least four groups of components peaked at 100, 140, 240, and 290 °C where the two lower overlapped temperature peaks are difficult to identify using the $T_M-T_{stop}$. The coexistence of a continuum in the trap distribution (linked to the lower temperature peaks) and a discrete trap system (associated with the components at temperatures higher than 200 °C) can be distinguished. The estimation of the TL kinetic parameters is performed using GlowFit, TLAnal, the spreadsheet Origin, Computing Glow Curve Deconvolution (CGCD), and various heating rate (VHR) methods. However, only CGCD appears as the suitable technique for such purpose since it provides information on the TL physical process supported by mathematical models based on a linear combination of functions related to the First Order Kinetic approach.
format Preprint
id arxiv_https___arxiv_org_abs_2406_01312
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle Kinetic Parameters analysis of GdAlO$_3$ based on thermoluminescent phenomenon
Nolasco-Altamirano, D.
Romero-Nuñez, C. S.
Alonso-Sotolongoza, A.
Benavente, J. F.
García-Salcedo, R.
García-Garduño, O. A.
Zarate-Medina, J.
Correcher, V.
Montalvo, T. Rivera
Materials Science
Instrumentation and Detectors
{We herein report on the calculation of thermoluminescence (TL) kinetic parameters determined from the TL emission of synthetic GdAlO3 (GAO) phosphors prepared by the co-precipitation method. The sample, characterized by means of X-ray diffraction with an orthorhombic phase structure (space group Pnma (62), shows complex glow curves consisting of at least four groups of components peaked at 100, 140, 240, and 290 °C where the two lower overlapped temperature peaks are difficult to identify using the $T_M-T_{stop}$. The coexistence of a continuum in the trap distribution (linked to the lower temperature peaks) and a discrete trap system (associated with the components at temperatures higher than 200 °C) can be distinguished. The estimation of the TL kinetic parameters is performed using GlowFit, TLAnal, the spreadsheet Origin, Computing Glow Curve Deconvolution (CGCD), and various heating rate (VHR) methods. However, only CGCD appears as the suitable technique for such purpose since it provides information on the TL physical process supported by mathematical models based on a linear combination of functions related to the First Order Kinetic approach.
title Kinetic Parameters analysis of GdAlO$_3$ based on thermoluminescent phenomenon
topic Materials Science
Instrumentation and Detectors
url https://arxiv.org/abs/2406.01312