Designing the system to measure the depth-dose profile of a proton beam using CsI(Tl) scintillator

Fuente: arXiv
Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Boontueng, P., Ritjoho, N., Phumara, P., Sanghangthum, T., Thongjerm, P., Wonglee, S., Pornroongruengchok, W., Kobdaj, C.
Format: Preprint
Veröffentlicht: 2024
Schlagworte:
Online-Zugang:
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
_version_ 1866911907668033536
author Boontueng, P.
Ritjoho, N.
Phumara, P.
Sanghangthum, T.
Thongjerm, P.
Wonglee, S.
Pornroongruengchok, W.
Kobdaj, C.
author_facet Boontueng, P.
Ritjoho, N.
Phumara, P.
Sanghangthum, T.
Thongjerm, P.
Wonglee, S.
Pornroongruengchok, W.
Kobdaj, C.
contents In this work, the standard CsI(Tl) scintillator was used to determine the characteristics of a proton beam. By irradiating the scintillator with a proton beam, it was able to subsequently measure the emitted light using a spectrometer. This work presents the dose response of a scintillator and its use to measure the depth-dose profile of a proton beam. The measurement of the dose response showed that the emission light of the scintillator depended on the total dose of the proton beam. For the design of the depth-dose measurement, the setup of the water phantom included a scintillator and a water tank. The depth-dose profile was determined through varying the water depth at various positions along the path of the proton beam until the end of the Bragg peak region. To compare the measured depth-dose profile, the deposited energy was simulated and fitted Birks constant for collecting quenching. Furthermore, the recommended measurement design suggested using a thin scintillator, as it resulted in a narrower shape of the depth-dose profile. Based on experiment and simulation data, a standard CsI(Tl) scintillator was promising for determining the characteristic proton beam.
format Preprint
id arxiv_https___arxiv_org_abs_2406_02571
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle Designing the system to measure the depth-dose profile of a proton beam using CsI(Tl) scintillator
Boontueng, P.
Ritjoho, N.
Phumara, P.
Sanghangthum, T.
Thongjerm, P.
Wonglee, S.
Pornroongruengchok, W.
Kobdaj, C.
Medical Physics
Nuclear Experiment
In this work, the standard CsI(Tl) scintillator was used to determine the characteristics of a proton beam. By irradiating the scintillator with a proton beam, it was able to subsequently measure the emitted light using a spectrometer. This work presents the dose response of a scintillator and its use to measure the depth-dose profile of a proton beam. The measurement of the dose response showed that the emission light of the scintillator depended on the total dose of the proton beam. For the design of the depth-dose measurement, the setup of the water phantom included a scintillator and a water tank. The depth-dose profile was determined through varying the water depth at various positions along the path of the proton beam until the end of the Bragg peak region. To compare the measured depth-dose profile, the deposited energy was simulated and fitted Birks constant for collecting quenching. Furthermore, the recommended measurement design suggested using a thin scintillator, as it resulted in a narrower shape of the depth-dose profile. Based on experiment and simulation data, a standard CsI(Tl) scintillator was promising for determining the characteristic proton beam.
title Designing the system to measure the depth-dose profile of a proton beam using CsI(Tl) scintillator
topic Medical Physics
Nuclear Experiment
url https://arxiv.org/abs/2406.02571