Single channel PICOSEC Micromegas detector with improved time resolution
Fuente:
arXiv
Salvato in:
| Autori principali: | , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , |
|---|---|
| Natura: | Preprint |
| Pubblicazione: |
2024
|
| Soggetti: | |
| Accesso online: | |
| Tags: |
Aggiungi Tag
Nessun Tag, puoi essere il primo ad aggiungerne!!
|
| _version_ | 1866929378785492992 |
|---|---|
| author | Utrobicic, A. Aleksan, R. Angelis, Y. Bortfeldt, J. Brunbauer, F. Brunoldi, M. Chatzianagnostou, E. Datta, J. Dehmelt, K. Fanourakis, G. Fiorina, D. Floethner, K. J. Gallinaro, M. Garcia, F. Giomataris, I. Gnanvo, K. Iguaz, F. J. Janssens, D. Kallitsopoulou, A. Kovacic, M. Kross, B. Legou, P. Lisowska, M. Liu, J. Lupberger, M. Maniatis, I. McKisson, J. Meng, Y. Muller, H. Oliveri, E. Orlandini, G. Pandey, A. Papaevangelou, T. Pomorski, M. Ropelewski, L. Sampsonidis, D. Scharenberg, L. Schneider, T. Sohl, L. van Stenis, M. Tsipolitis, Y. Tzamarias, S. E. Vai, I. Veenhof, R. Vitulo, P. Wang, X. White, S. Xi, W. Zhang, Z. Zhou, Y. |
| author_facet | Utrobicic, A. Aleksan, R. Angelis, Y. Bortfeldt, J. Brunbauer, F. Brunoldi, M. Chatzianagnostou, E. Datta, J. Dehmelt, K. Fanourakis, G. Fiorina, D. Floethner, K. J. Gallinaro, M. Garcia, F. Giomataris, I. Gnanvo, K. Iguaz, F. J. Janssens, D. Kallitsopoulou, A. Kovacic, M. Kross, B. Legou, P. Lisowska, M. Liu, J. Lupberger, M. Maniatis, I. McKisson, J. Meng, Y. Muller, H. Oliveri, E. Orlandini, G. Pandey, A. Papaevangelou, T. Pomorski, M. Ropelewski, L. Sampsonidis, D. Scharenberg, L. Schneider, T. Sohl, L. van Stenis, M. Tsipolitis, Y. Tzamarias, S. E. Vai, I. Veenhof, R. Vitulo, P. Wang, X. White, S. Xi, W. Zhang, Z. Zhou, Y. |
| contents | This paper presents design guidelines and experimental verification of a single-channel PICOSEC Micromegas (MM) detector with an improved time resolution. The design encompasses the detector board, vessel, auxiliary mechanical parts, and electrical connectivity for high voltage (HV) and signals, focusing on improving stability, reducing noise, and ensuring signal integrity to optimize timing performance. A notable feature is the simple and fast reassembly procedure, facilitating quick replacement of detector internal components that allows for an efficient measurement strategy involving different detector components. The paper also examines the influence of parasitics on the output signal integrity. To validate the design, a prototype assembly and three interchangeable detector boards with varying readout pad diameters were manufactured. The detectors were initially tested in the laboratory environment. Finally, the timing performance of detectors with different pad sizes was verified using a Minimum Ionizing Particle (MIP) beam test. Notably, a record time resolution for a PICOSEC Micromegas detector technology with a CsI photocathode of 12.5$\pm$0.8 ps was achieved with a 10 mm diameter readout pad size detector. |
| format | Preprint |
| id |
arxiv_https___arxiv_org_abs_2406_05657 |
| institution | arXiv |
| publishDate | 2024 |
| record_format | arxiv |
| spellingShingle | Single channel PICOSEC Micromegas detector with improved time resolution Utrobicic, A. Aleksan, R. Angelis, Y. Bortfeldt, J. Brunbauer, F. Brunoldi, M. Chatzianagnostou, E. Datta, J. Dehmelt, K. Fanourakis, G. Fiorina, D. Floethner, K. J. Gallinaro, M. Garcia, F. Giomataris, I. Gnanvo, K. Iguaz, F. J. Janssens, D. Kallitsopoulou, A. Kovacic, M. Kross, B. Legou, P. Lisowska, M. Liu, J. Lupberger, M. Maniatis, I. McKisson, J. Meng, Y. Muller, H. Oliveri, E. Orlandini, G. Pandey, A. Papaevangelou, T. Pomorski, M. Ropelewski, L. Sampsonidis, D. Scharenberg, L. Schneider, T. Sohl, L. van Stenis, M. Tsipolitis, Y. Tzamarias, S. E. Vai, I. Veenhof, R. Vitulo, P. Wang, X. White, S. Xi, W. Zhang, Z. Zhou, Y. Instrumentation and Detectors This paper presents design guidelines and experimental verification of a single-channel PICOSEC Micromegas (MM) detector with an improved time resolution. The design encompasses the detector board, vessel, auxiliary mechanical parts, and electrical connectivity for high voltage (HV) and signals, focusing on improving stability, reducing noise, and ensuring signal integrity to optimize timing performance. A notable feature is the simple and fast reassembly procedure, facilitating quick replacement of detector internal components that allows for an efficient measurement strategy involving different detector components. The paper also examines the influence of parasitics on the output signal integrity. To validate the design, a prototype assembly and three interchangeable detector boards with varying readout pad diameters were manufactured. The detectors were initially tested in the laboratory environment. Finally, the timing performance of detectors with different pad sizes was verified using a Minimum Ionizing Particle (MIP) beam test. Notably, a record time resolution for a PICOSEC Micromegas detector technology with a CsI photocathode of 12.5$\pm$0.8 ps was achieved with a 10 mm diameter readout pad size detector. |
| title | Single channel PICOSEC Micromegas detector with improved time resolution |
| topic | Instrumentation and Detectors |
| url | https://arxiv.org/abs/2406.05657 |