Error analysis of vertical test for CEPC 650 MHz superconducting radio-frequency cavity

Fuente: arXiv
Salvato in:
Dettagli Bibliografici
Autori principali: Ye, Lingxi, Sha, Peng, Mi, Zhenghui, He, Feisi, Zhai, Jiyuan
Natura: Preprint
Pubblicazione: 2024
Soggetti:
Accesso online:
Tags: Aggiungi Tag
Nessun Tag, puoi essere il primo ad aggiungerne!!
_version_ 1866916280310693888
author Ye, Lingxi
Sha, Peng
Mi, Zhenghui
He, Feisi
Zhai, Jiyuan
author_facet Ye, Lingxi
Sha, Peng
Mi, Zhenghui
He, Feisi
Zhai, Jiyuan
contents Hundreds of 650 MHz superconducting radio-frequency (SRF) cavities with high intrinsic quality factor (Q0) and accelerating gradient (Eacc) will be adopted for Circular Electron Positron Collider (CEPC). The values of Q0 and Eacc are obtained during vertical test at 2.0 K. Hence, high accuracy of vertical test is essential for evaluating the performance of SRF cavity. The 650 MHz SRF cavities achieved very high Q0 (6E10) and Eacc (40 MV/m) during the vertical test. In our study, the error analysis of vertical test was conducted in the scalar case, in order to achieve high accuracy. The uncertainties of vertical test were obtained through calculation, which was approximately 3% for Eacc and less than 5% for Q0. This result was reasonable and acceptable.
format Preprint
id arxiv_https___arxiv_org_abs_2406_05715
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle Error analysis of vertical test for CEPC 650 MHz superconducting radio-frequency cavity
Ye, Lingxi
Sha, Peng
Mi, Zhenghui
He, Feisi
Zhai, Jiyuan
Accelerator Physics
High Energy Physics - Experiment
Hundreds of 650 MHz superconducting radio-frequency (SRF) cavities with high intrinsic quality factor (Q0) and accelerating gradient (Eacc) will be adopted for Circular Electron Positron Collider (CEPC). The values of Q0 and Eacc are obtained during vertical test at 2.0 K. Hence, high accuracy of vertical test is essential for evaluating the performance of SRF cavity. The 650 MHz SRF cavities achieved very high Q0 (6E10) and Eacc (40 MV/m) during the vertical test. In our study, the error analysis of vertical test was conducted in the scalar case, in order to achieve high accuracy. The uncertainties of vertical test were obtained through calculation, which was approximately 3% for Eacc and less than 5% for Q0. This result was reasonable and acceptable.
title Error analysis of vertical test for CEPC 650 MHz superconducting radio-frequency cavity
topic Accelerator Physics
High Energy Physics - Experiment
url https://arxiv.org/abs/2406.05715