Increased accuracy and signal-to-noise ratio through recent improvements in Infra-Red Video Bolometer fabrication and calibration

Fuente: arXiv
Saved in:
Bibliographic Details
Main Authors: Federici, Fabio, Lovell, Jack J., Wurden, G. A., Peterson, Byron J., Mukai, Kiyofumi
Format: Preprint
Published: 2024
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866916575738593280
author Federici, Fabio
Lovell, Jack J.
Wurden, G. A.
Peterson, Byron J.
Mukai, Kiyofumi
author_facet Federici, Fabio
Lovell, Jack J.
Wurden, G. A.
Peterson, Byron J.
Mukai, Kiyofumi
contents The Infra-Red Video Bolometer (IRVB) is a diagnostic equipped with an infra-red camera that measures the total radiated power in thousands of LOSs within a large field of view (FOV). Recently validated in MAST-U, it offers a high spatial resolution map of the radiated power in the divertor region, where large gradients are expected. The IRVB's sensing element comprises a thin layer of high Z absorbing material, typically Platinum, usually coated with Carbon to reduce reflections. It is here explored the possibility of using a relatively inert material like Titanium, that can be produced in layers up to 1mum compared to 2.5mum for Pt, and then coat it with Pt of the desired thickness (0.3mum per side here) and Carbon. This leads to a higher temperature signal (2 to 3 times), and better spatial resolution (about 4 times), resulting in higher accuracy in the measured power. This assembly is also expected to improve foil uniformity, as the Pt layer is obtained via deposition rather than mechanical processes. Given its multi-material composition, measuring the thermal properties of the foil assembly is vital. Various methods using a calibrated laser as a heat source have been developed, analysing the temperature profile shape or fitting the calculated laser power for different intensities and frequencies. It is here presented a simpler approach, that relies on analysing the separate components of the foil heat equation for a single laser exposure in a given area. This can then be iterated over the entire foil to capture local deviations.
format Preprint
id arxiv_https___arxiv_org_abs_2406_07139
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle Increased accuracy and signal-to-noise ratio through recent improvements in Infra-Red Video Bolometer fabrication and calibration
Federici, Fabio
Lovell, Jack J.
Wurden, G. A.
Peterson, Byron J.
Mukai, Kiyofumi
Plasma Physics
Instrumentation and Detectors
The Infra-Red Video Bolometer (IRVB) is a diagnostic equipped with an infra-red camera that measures the total radiated power in thousands of LOSs within a large field of view (FOV). Recently validated in MAST-U, it offers a high spatial resolution map of the radiated power in the divertor region, where large gradients are expected. The IRVB's sensing element comprises a thin layer of high Z absorbing material, typically Platinum, usually coated with Carbon to reduce reflections. It is here explored the possibility of using a relatively inert material like Titanium, that can be produced in layers up to 1mum compared to 2.5mum for Pt, and then coat it with Pt of the desired thickness (0.3mum per side here) and Carbon. This leads to a higher temperature signal (2 to 3 times), and better spatial resolution (about 4 times), resulting in higher accuracy in the measured power. This assembly is also expected to improve foil uniformity, as the Pt layer is obtained via deposition rather than mechanical processes. Given its multi-material composition, measuring the thermal properties of the foil assembly is vital. Various methods using a calibrated laser as a heat source have been developed, analysing the temperature profile shape or fitting the calculated laser power for different intensities and frequencies. It is here presented a simpler approach, that relies on analysing the separate components of the foil heat equation for a single laser exposure in a given area. This can then be iterated over the entire foil to capture local deviations.
title Increased accuracy and signal-to-noise ratio through recent improvements in Infra-Red Video Bolometer fabrication and calibration
topic Plasma Physics
Instrumentation and Detectors
url https://arxiv.org/abs/2406.07139