A directional total variation minimization algorithm for isotropic resolution in digital breast tomosynthesis

Fuente: arXiv
Guardado en:
Detalles Bibliográficos
Autores principales: Sidky, Emil Y., Wu, Xiangyi, Duan, Xiaoyu, Huang, Hailing, Zhao, Wei, Zhang, Leo Y., Phillips, John Paul, Zhang, Zheng, Chen, Buxin, Xia, Dan, Reiser, Ingrid S., Pan, Xiaochuan
Formato: Preprint
Publicado: 2024
Materias:
Acceso en línea:
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
_version_ 1866914831705047040
author Sidky, Emil Y.
Wu, Xiangyi
Duan, Xiaoyu
Huang, Hailing
Zhao, Wei
Zhang, Leo Y.
Phillips, John Paul
Zhang, Zheng
Chen, Buxin
Xia, Dan
Reiser, Ingrid S.
Pan, Xiaochuan
author_facet Sidky, Emil Y.
Wu, Xiangyi
Duan, Xiaoyu
Huang, Hailing
Zhao, Wei
Zhang, Leo Y.
Phillips, John Paul
Zhang, Zheng
Chen, Buxin
Xia, Dan
Reiser, Ingrid S.
Pan, Xiaochuan
contents An optimization-based image reconstruction algorithm is developed for contrast enhanced digital breast tomosynthesis (DBT) using dual-energy scanning. The algorithm minimizes directional total variation (TV) with a data discrepancy and non-negativity constraints. Iodinated contrast agent (ICA) imaging is performed by reconstructing images from dual-energy DBT data followed by weighted subtraction. Physical DBT data is acquired with a Siemens Mammomat scanner of a structured breast phantom with ICA inserts. Results are shown for both directional TV minimization and filtered back-projection for reference. It is seen that directional TV is able to substantially reduce depth blur for the ICA objects.
format Preprint
id arxiv_https___arxiv_org_abs_2406_07306
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle A directional total variation minimization algorithm for isotropic resolution in digital breast tomosynthesis
Sidky, Emil Y.
Wu, Xiangyi
Duan, Xiaoyu
Huang, Hailing
Zhao, Wei
Zhang, Leo Y.
Phillips, John Paul
Zhang, Zheng
Chen, Buxin
Xia, Dan
Reiser, Ingrid S.
Pan, Xiaochuan
Medical Physics
An optimization-based image reconstruction algorithm is developed for contrast enhanced digital breast tomosynthesis (DBT) using dual-energy scanning. The algorithm minimizes directional total variation (TV) with a data discrepancy and non-negativity constraints. Iodinated contrast agent (ICA) imaging is performed by reconstructing images from dual-energy DBT data followed by weighted subtraction. Physical DBT data is acquired with a Siemens Mammomat scanner of a structured breast phantom with ICA inserts. Results are shown for both directional TV minimization and filtered back-projection for reference. It is seen that directional TV is able to substantially reduce depth blur for the ICA objects.
title A directional total variation minimization algorithm for isotropic resolution in digital breast tomosynthesis
topic Medical Physics
url https://arxiv.org/abs/2406.07306