Single MoS2-flake as a high TCR non-cryogenic bolometer

Fuente: arXiv
Saved in:
Bibliographic Details
Main Authors: Khan, Saba M., Saini, Jyoti, Kundu, Anirban, Rani, Renu, Hazra, Kiran S.
Format: Preprint
Published: 2024
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866910482907004928
author Khan, Saba M.
Saini, Jyoti
Kundu, Anirban
Rani, Renu
Hazra, Kiran S.
author_facet Khan, Saba M.
Saini, Jyoti
Kundu, Anirban
Rani, Renu
Hazra, Kiran S.
contents Temperature coefficient of resistance (TCR) of a bolometer can be tuned by modifying the thermal conductance of an absorbing materials since they sense radiations via the temperature change in the absorber. However, the thermal conductance of the absorber can be reduced by engineering the appropriate thermal isolation, which can be an ultimate solution towards making a highly sensitive thermal detector. Here, we have developed an atomically thin 2D bolometer detector made up of a mechanically transferred suspended multilayer-MoS2 flake, eliminating the use of challenging thin-film fabrication process. The strength of our detector lies on the two factors: its large surface-to-volume window to absorb the radiations; the suspended configuration which prevents the heat dissipation through the substrate and therefore reduces the thermal conductance. The bolometric response of the detector is tested in both modes, via the photoresponse and the thermal response. The prototype is found to exhibit a very high TCR ~ -9.5%/K with the least achievable thermal noise-equivalent power (NEP) ~ 0.61 pWHz-1/2, in ambient conditions at 328 K.
format Preprint
id arxiv_https___arxiv_org_abs_2406_07818
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle Single MoS2-flake as a high TCR non-cryogenic bolometer
Khan, Saba M.
Saini, Jyoti
Kundu, Anirban
Rani, Renu
Hazra, Kiran S.
Applied Physics
Materials Science
Instrumentation and Detectors
Optics
Temperature coefficient of resistance (TCR) of a bolometer can be tuned by modifying the thermal conductance of an absorbing materials since they sense radiations via the temperature change in the absorber. However, the thermal conductance of the absorber can be reduced by engineering the appropriate thermal isolation, which can be an ultimate solution towards making a highly sensitive thermal detector. Here, we have developed an atomically thin 2D bolometer detector made up of a mechanically transferred suspended multilayer-MoS2 flake, eliminating the use of challenging thin-film fabrication process. The strength of our detector lies on the two factors: its large surface-to-volume window to absorb the radiations; the suspended configuration which prevents the heat dissipation through the substrate and therefore reduces the thermal conductance. The bolometric response of the detector is tested in both modes, via the photoresponse and the thermal response. The prototype is found to exhibit a very high TCR ~ -9.5%/K with the least achievable thermal noise-equivalent power (NEP) ~ 0.61 pWHz-1/2, in ambient conditions at 328 K.
title Single MoS2-flake as a high TCR non-cryogenic bolometer
topic Applied Physics
Materials Science
Instrumentation and Detectors
Optics
url https://arxiv.org/abs/2406.07818