Towards a sub-kelvin cryogenic Fabry-Perot silicon cavity

Fuente: arXiv
Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Barbarat, Joannès, Gillot, Jonathan, Millo, Jacques, Lacroûte, Clément, Legero, Thomas, Giordano, Vincent, Kersalé, Yann
Format: Preprint
Veröffentlicht: 2024
Schlagworte:
Online-Zugang:
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
_version_ 1866911914508943360
author Barbarat, Joannès
Gillot, Jonathan
Millo, Jacques
Lacroûte, Clément
Legero, Thomas
Giordano, Vincent
Kersalé, Yann
author_facet Barbarat, Joannès
Gillot, Jonathan
Millo, Jacques
Lacroûte, Clément
Legero, Thomas
Giordano, Vincent
Kersalé, Yann
contents We report on the development of a sub-kelvin, single-crystal silicon Fabry-Perot cavity. Operating such a cavity below 1~K should reduce the thermal noise limit of the cavity, and by this way address the current limitations of ultrastable lasers. To further decrease mechanical losses, mirrors with silicon substrates and crystalline coatings are optically contacted to the spacer, resulting in a room-temperature finesse of 220,000. To operate our cavity at sub-kelvin temperatures, we use a dilution refrigerator able to reach temperatures down to 10 mK. We have designed a mechanical mount to house our cavity in such a cryostat, with optimized heat transfer that will decrease the cooldown time for temperatures below 1~K. The estimated thermal noise is projected to be $\sim 7{\times}10^{-19}$ at 100~mK. However, silicon cavities with crystalline mirror coatings at cryogenic temperatures have shown birefringence correlated frequency fluctuations as well as unknown additional noise mechanisms \cite{yu2023, kedar2023}. We have measured a room-temperature TEM$_{00}$ birefringent mode splitting of about 250 kHz. Understanding and measuring these noise mechanisms will be a key to attaining fractional frequency stabilities beyond state-of-the-art.
format Preprint
id arxiv_https___arxiv_org_abs_2406_08256
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle Towards a sub-kelvin cryogenic Fabry-Perot silicon cavity
Barbarat, Joannès
Gillot, Jonathan
Millo, Jacques
Lacroûte, Clément
Legero, Thomas
Giordano, Vincent
Kersalé, Yann
Instrumentation and Detectors
Atomic Physics
Optics
We report on the development of a sub-kelvin, single-crystal silicon Fabry-Perot cavity. Operating such a cavity below 1~K should reduce the thermal noise limit of the cavity, and by this way address the current limitations of ultrastable lasers. To further decrease mechanical losses, mirrors with silicon substrates and crystalline coatings are optically contacted to the spacer, resulting in a room-temperature finesse of 220,000. To operate our cavity at sub-kelvin temperatures, we use a dilution refrigerator able to reach temperatures down to 10 mK. We have designed a mechanical mount to house our cavity in such a cryostat, with optimized heat transfer that will decrease the cooldown time for temperatures below 1~K. The estimated thermal noise is projected to be $\sim 7{\times}10^{-19}$ at 100~mK. However, silicon cavities with crystalline mirror coatings at cryogenic temperatures have shown birefringence correlated frequency fluctuations as well as unknown additional noise mechanisms \cite{yu2023, kedar2023}. We have measured a room-temperature TEM$_{00}$ birefringent mode splitting of about 250 kHz. Understanding and measuring these noise mechanisms will be a key to attaining fractional frequency stabilities beyond state-of-the-art.
title Towards a sub-kelvin cryogenic Fabry-Perot silicon cavity
topic Instrumentation and Detectors
Atomic Physics
Optics
url https://arxiv.org/abs/2406.08256