Investigation of reflection-based measurements of microwave kinetic inductance detectors in the optical bands

Fuente: arXiv
Salvato in:
Dettagli Bibliografici
Autori principali: Hu, Jie, Boussaha, Faouzi, Nicaise, Paul, Chaumont, Christine, Appavou, Maria, Pham, Viet Dung, Piat, Michel
Natura: Preprint
Pubblicazione: 2024
Soggetti:
Accesso online:
Tags: Aggiungi Tag
Nessun Tag, puoi essere il primo ad aggiungerne!!
_version_ 1866914833815830528
author Hu, Jie
Boussaha, Faouzi
Nicaise, Paul
Chaumont, Christine
Appavou, Maria
Pham, Viet Dung
Piat, Michel
author_facet Hu, Jie
Boussaha, Faouzi
Nicaise, Paul
Chaumont, Christine
Appavou, Maria
Pham, Viet Dung
Piat, Michel
contents In this paper, we investigate the single photon response from the reflection of the Microwave Kinetic Inductance Detector (MKID) array. Reflection measurements are carried out using two configurations: one is measured simultaneously with the transmission, and the other is obtained with a single-ended MKID array terminated with an open load. Compared with the transmission, reflection measurements significantly reduce the readout noise of the single-ended MKID array. This is also reflected in the improvement of the median energy resolving power by around 20%-30% under pulsed photon illumination at $λ= 405$~nm, mainly due to an increase in the size of the resonance circle on the IQ plane. This method has the potential to be used to read out large MKID arrays.
format Preprint
id arxiv_https___arxiv_org_abs_2406_09436
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle Investigation of reflection-based measurements of microwave kinetic inductance detectors in the optical bands
Hu, Jie
Boussaha, Faouzi
Nicaise, Paul
Chaumont, Christine
Appavou, Maria
Pham, Viet Dung
Piat, Michel
Instrumentation and Methods for Astrophysics
In this paper, we investigate the single photon response from the reflection of the Microwave Kinetic Inductance Detector (MKID) array. Reflection measurements are carried out using two configurations: one is measured simultaneously with the transmission, and the other is obtained with a single-ended MKID array terminated with an open load. Compared with the transmission, reflection measurements significantly reduce the readout noise of the single-ended MKID array. This is also reflected in the improvement of the median energy resolving power by around 20%-30% under pulsed photon illumination at $λ= 405$~nm, mainly due to an increase in the size of the resonance circle on the IQ plane. This method has the potential to be used to read out large MKID arrays.
title Investigation of reflection-based measurements of microwave kinetic inductance detectors in the optical bands
topic Instrumentation and Methods for Astrophysics
url https://arxiv.org/abs/2406.09436