An insertable glucose sensor using a compact and cost-effective phosphorescence lifetime imager and machine learning

Fuente: arXiv
Enregistré dans:
Détails bibliographiques
Auteurs principaux: Goncharov, Artem, Gorocs, Zoltan, Pradhan, Ridhi, Ko, Brian, Ajmal, Ajmal, Rodriguez, Andres, Baum, David, Veszpremi, Marcell, Yang, Xilin, Pindrys, Maxime, Zheng, Tianle, Wang, Oliver, Ramella-Roman, Jessica C., McShane, Michael J., Ozcan, Aydogan
Format: Preprint
Publié: 2024
Sujets:
Accès en ligne:
Tags: Ajouter un tag
Pas de tags, Soyez le premier à ajouter un tag!
_version_ 1866909286450331648
author Goncharov, Artem
Gorocs, Zoltan
Pradhan, Ridhi
Ko, Brian
Ajmal, Ajmal
Rodriguez, Andres
Baum, David
Veszpremi, Marcell
Yang, Xilin
Pindrys, Maxime
Zheng, Tianle
Wang, Oliver
Ramella-Roman, Jessica C.
McShane, Michael J.
Ozcan, Aydogan
author_facet Goncharov, Artem
Gorocs, Zoltan
Pradhan, Ridhi
Ko, Brian
Ajmal, Ajmal
Rodriguez, Andres
Baum, David
Veszpremi, Marcell
Yang, Xilin
Pindrys, Maxime
Zheng, Tianle
Wang, Oliver
Ramella-Roman, Jessica C.
McShane, Michael J.
Ozcan, Aydogan
contents Optical continuous glucose monitoring (CGM) systems are emerging for personalized glucose management owing to their lower cost and prolonged durability compared to conventional electrochemical CGMs. Here, we report a computational CGM system, which integrates a biocompatible phosphorescence-based insertable biosensor and a custom-designed phosphorescence lifetime imager (PLI). This compact and cost-effective PLI is designed to capture phosphorescence lifetime images of an insertable sensor through the skin, where the lifetime of the emitted phosphorescence signal is modulated by the local concentration of glucose. Because this phosphorescence signal has a very long lifetime compared to tissue autofluorescence or excitation leakage processes, it completely bypasses these noise sources by measuring the sensor emission over several tens of microseconds after the excitation light is turned off. The lifetime images acquired through the skin are processed by neural network-based models for misalignment-tolerant inference of glucose levels, accurately revealing normal, low (hypoglycemia) and high (hyperglycemia) concentration ranges. Using a 1-mm thick skin phantom mimicking the optical properties of human skin, we performed in vitro testing of the PLI using glucose-spiked samples, yielding 88.8% inference accuracy, also showing resilience to random and unknown misalignments within a lateral distance of ~4.7 mm with respect to the position of the insertable sensor underneath the skin phantom. Furthermore, the PLI accurately identified larger lateral misalignments beyond 5 mm, prompting user intervention for re-alignment. The misalignment-resilient glucose concentration inference capability of this compact and cost-effective phosphorescence lifetime imager makes it an appealing wearable diagnostics tool for real-time tracking of glucose and other biomarkers.
format Preprint
id arxiv_https___arxiv_org_abs_2406_09442
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle An insertable glucose sensor using a compact and cost-effective phosphorescence lifetime imager and machine learning
Goncharov, Artem
Gorocs, Zoltan
Pradhan, Ridhi
Ko, Brian
Ajmal, Ajmal
Rodriguez, Andres
Baum, David
Veszpremi, Marcell
Yang, Xilin
Pindrys, Maxime
Zheng, Tianle
Wang, Oliver
Ramella-Roman, Jessica C.
McShane, Michael J.
Ozcan, Aydogan
Medical Physics
Machine Learning
Applied Physics
Biological Physics
Optical continuous glucose monitoring (CGM) systems are emerging for personalized glucose management owing to their lower cost and prolonged durability compared to conventional electrochemical CGMs. Here, we report a computational CGM system, which integrates a biocompatible phosphorescence-based insertable biosensor and a custom-designed phosphorescence lifetime imager (PLI). This compact and cost-effective PLI is designed to capture phosphorescence lifetime images of an insertable sensor through the skin, where the lifetime of the emitted phosphorescence signal is modulated by the local concentration of glucose. Because this phosphorescence signal has a very long lifetime compared to tissue autofluorescence or excitation leakage processes, it completely bypasses these noise sources by measuring the sensor emission over several tens of microseconds after the excitation light is turned off. The lifetime images acquired through the skin are processed by neural network-based models for misalignment-tolerant inference of glucose levels, accurately revealing normal, low (hypoglycemia) and high (hyperglycemia) concentration ranges. Using a 1-mm thick skin phantom mimicking the optical properties of human skin, we performed in vitro testing of the PLI using glucose-spiked samples, yielding 88.8% inference accuracy, also showing resilience to random and unknown misalignments within a lateral distance of ~4.7 mm with respect to the position of the insertable sensor underneath the skin phantom. Furthermore, the PLI accurately identified larger lateral misalignments beyond 5 mm, prompting user intervention for re-alignment. The misalignment-resilient glucose concentration inference capability of this compact and cost-effective phosphorescence lifetime imager makes it an appealing wearable diagnostics tool for real-time tracking of glucose and other biomarkers.
title An insertable glucose sensor using a compact and cost-effective phosphorescence lifetime imager and machine learning
topic Medical Physics
Machine Learning
Applied Physics
Biological Physics
url https://arxiv.org/abs/2406.09442