contents In an axion haloscope, the weak photon signal, theoretically converted from axions, is captured by a detection cavity. The signal from the cavity is too weak to be acquired by a signal receiver. The amplification chain assists the signal acquisition by amplifying the signal and requires accurate gain calibration. Typically, the readout line is calibrated using the Y-factor method, involving a switch that directs either the detection line or the calibration line to the amplification chain. The detection and calibration lines may have different transmissions, which leads to the calibration results being less accurate. In response, we propose a calibration method that eliminates the need for a switch. In this approach, the cavity temperature is decoupled to its incoming noise source and can be controlled, resulting in excess or deficiency of the noise spectrum near its resonance frequency. The experimental result shows that the gain of the amplification chain can be calibrated directly using the temperature-varied cavity radiation.
format Preprint
id arxiv_https___arxiv_org_abs_2406_13350
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle Direct calibration of microwave amplification chain on an axion cavity haloscope
Chang, Hsin
Liu, Han-Wen
Doan, Hien Thi
Chen, Yung-Fu
Instrumentation and Detectors
Applied Physics
In an axion haloscope, the weak photon signal, theoretically converted from axions, is captured by a detection cavity. The signal from the cavity is too weak to be acquired by a signal receiver. The amplification chain assists the signal acquisition by amplifying the signal and requires accurate gain calibration. Typically, the readout line is calibrated using the Y-factor method, involving a switch that directs either the detection line or the calibration line to the amplification chain. The detection and calibration lines may have different transmissions, which leads to the calibration results being less accurate. In response, we propose a calibration method that eliminates the need for a switch. In this approach, the cavity temperature is decoupled to its incoming noise source and can be controlled, resulting in excess or deficiency of the noise spectrum near its resonance frequency. The experimental result shows that the gain of the amplification chain can be calibrated directly using the temperature-varied cavity radiation.
title Direct calibration of microwave amplification chain on an axion cavity haloscope
topic Instrumentation and Detectors
Applied Physics
url https://arxiv.org/abs/2406.13350