3D distortion-free, reduced field of view diffusion-prepared GRE at 3T

Fuente: arXiv
Guardado en:
Detalles Bibliográficos
Autores principales: McElroy, Sarah, Tomi-Tricot, Raphael, Cleary, Jon, Kinsella, Shawna, Jeljeli, Sami, Goh, Vicky, Neji, Radhouene
Formato: Preprint
Publicado: 2024
Materias:
Acceso en línea:
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
_version_ 1866914847467241472
author McElroy, Sarah
Tomi-Tricot, Raphael
Cleary, Jon
Kinsella, Shawna
Jeljeli, Sami
Goh, Vicky
Neji, Radhouene
author_facet McElroy, Sarah
Tomi-Tricot, Raphael
Cleary, Jon
Kinsella, Shawna
Jeljeli, Sami
Goh, Vicky
Neji, Radhouene
contents Purpose: To develop a 3D distortion-free reduced-FOV diffusion-prepared GRE sequence and demonstrate its in-vivo application for diffusion imaging of the spinal cord in healthy volunteers. Methods: A 3D multi-shot reduced-FOV diffusion-prepared GRE (RFOV-DP-GRE) acquisition is achieved using a slice-selective tip-down pulse in the phase encoding direction in the diffusion preparation, combined with magnitude stabilisers. The efficacy of the developed reduced FOV approach and accuracy of ADC estimates were evaluated in a phantom. In addition, 5 healthy volunteers were enrolled and scanned at 3T using the proposed sequence and a standard spin echo diffusion-weighted single-shot EPI sequence (DW-SS-EPI) for spinal cord imaging. Image quality, perceived SNR and image distortion were assessed by two expert readers and quantitative measurements of apparent SNR were performed. Results: The phantom scan demonstrates the efficacy of the proposed reduced FOV approach. Consistent ADC estimates were measured with RFOV-DP-GRE when compared with DW-SS-EPI. In-vivo, RFOV-DP-GRE demonstrated improved image quality and reduced perceived distortion, while maintaining perceived SNR compared to DW-SS-EPI. Conclusion: 3D Distortion-free diffusion-prepared imaging can be achieved using the proposed sequence
format Preprint
id arxiv_https___arxiv_org_abs_2406_16809
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle 3D distortion-free, reduced field of view diffusion-prepared GRE at 3T
McElroy, Sarah
Tomi-Tricot, Raphael
Cleary, Jon
Kinsella, Shawna
Jeljeli, Sami
Goh, Vicky
Neji, Radhouene
Medical Physics
Purpose: To develop a 3D distortion-free reduced-FOV diffusion-prepared GRE sequence and demonstrate its in-vivo application for diffusion imaging of the spinal cord in healthy volunteers. Methods: A 3D multi-shot reduced-FOV diffusion-prepared GRE (RFOV-DP-GRE) acquisition is achieved using a slice-selective tip-down pulse in the phase encoding direction in the diffusion preparation, combined with magnitude stabilisers. The efficacy of the developed reduced FOV approach and accuracy of ADC estimates were evaluated in a phantom. In addition, 5 healthy volunteers were enrolled and scanned at 3T using the proposed sequence and a standard spin echo diffusion-weighted single-shot EPI sequence (DW-SS-EPI) for spinal cord imaging. Image quality, perceived SNR and image distortion were assessed by two expert readers and quantitative measurements of apparent SNR were performed. Results: The phantom scan demonstrates the efficacy of the proposed reduced FOV approach. Consistent ADC estimates were measured with RFOV-DP-GRE when compared with DW-SS-EPI. In-vivo, RFOV-DP-GRE demonstrated improved image quality and reduced perceived distortion, while maintaining perceived SNR compared to DW-SS-EPI. Conclusion: 3D Distortion-free diffusion-prepared imaging can be achieved using the proposed sequence
title 3D distortion-free, reduced field of view diffusion-prepared GRE at 3T
topic Medical Physics
url https://arxiv.org/abs/2406.16809