contents The Thermo Scientific P385 Neutron Generator is a compact neutron source, producing 14 MeV neutrons through the deuterium-tritium (DT) fusion reaction. For practical use, it is important to measure and preferably understand the dependence of the neutron production rate on the accelerator current and voltage. In this study, we evaluated neutron production with a neutron spectrometer (BTI N-Probe), a He-3 detector surrounded by HDPE shells (Nested Neutron Spectrometer, NNS), and two ZnS fast neutron scintillators (EJ-410) for both P385 A3082 and A3083 sealed tubes. We also predicted the neutron yield using the TRIM code, which calculates the trajectory and the energy loss of deuterons and tritons within the target. Experimental and theoretical results showed a linear dependence on beam current and a $\sim$3.5 power law dependence on the operating voltage. A series of NNS measurements, neutron spectrum from N-Probe and MCNP calculation showed that the A3083 and A3082 tubes provide a maximum neutron yield of $\sim 8.2 \times 10^8$ n/s and $\sim 4.5 \times 10^8$ n/s, respectively. We showed that tritium decay was not a significant contributor to this difference.
format Preprint
id arxiv_https___arxiv_org_abs_2406_18607
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle Neutron Yield of Thermo Scientific P385 D-T Neutron Generator vs. Current and Voltage
Jeon, Jihye
Goldston, Robert J.
Gilson, Erik P.
Instrumentation and Detectors
The Thermo Scientific P385 Neutron Generator is a compact neutron source, producing 14 MeV neutrons through the deuterium-tritium (DT) fusion reaction. For practical use, it is important to measure and preferably understand the dependence of the neutron production rate on the accelerator current and voltage. In this study, we evaluated neutron production with a neutron spectrometer (BTI N-Probe), a He-3 detector surrounded by HDPE shells (Nested Neutron Spectrometer, NNS), and two ZnS fast neutron scintillators (EJ-410) for both P385 A3082 and A3083 sealed tubes. We also predicted the neutron yield using the TRIM code, which calculates the trajectory and the energy loss of deuterons and tritons within the target. Experimental and theoretical results showed a linear dependence on beam current and a $\sim$3.5 power law dependence on the operating voltage. A series of NNS measurements, neutron spectrum from N-Probe and MCNP calculation showed that the A3083 and A3082 tubes provide a maximum neutron yield of $\sim 8.2 \times 10^8$ n/s and $\sim 4.5 \times 10^8$ n/s, respectively. We showed that tritium decay was not a significant contributor to this difference.
title Neutron Yield of Thermo Scientific P385 D-T Neutron Generator vs. Current and Voltage
topic Instrumentation and Detectors
url https://arxiv.org/abs/2406.18607