Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Sivayogaraj, Kaushalya, Guruge, Sahan T., Liyanage, Udari, Udupihille, Jeevani, Jayasinghe, Saroj, Fernando, Gerard, Rodrigo, Ranga, Liyanaarachchi, M. Rukshani
Format: Preprint
Veröffentlicht: 2024
Schlagworte:
Online-Zugang:https://arxiv.org/abs/2406.19336
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
_version_ 1866916410485112832
author Sivayogaraj, Kaushalya
Guruge, Sahan T.
Liyanage, Udari
Udupihille, Jeevani
Jayasinghe, Saroj
Fernando, Gerard
Rodrigo, Ranga
Liyanaarachchi, M. Rukshani
author_facet Sivayogaraj, Kaushalya
Guruge, Sahan T.
Liyanage, Udari
Udupihille, Jeevani
Jayasinghe, Saroj
Fernando, Gerard
Rodrigo, Ranga
Liyanaarachchi, M. Rukshani
contents 3D reconstruction of the liver for volumetry is important for qualitative analysis and disease diagnosis. Liver volumetry using ultrasound (US) scans, although advantageous due to less acquisition time and safety, is challenging due to the inherent noisiness in US scans, blurry boundaries, and partial liver visibility. We address these challenges by using the segmentation masks of a few incomplete sagittal-plane US scans of the liver in conjunction with a statistical shape model (SSM) built using a set of CT scans of the liver. We compute the shape parameters needed to warp this canonical SSM to fit the US scans through a parametric regression network. The resulting 3D liver reconstruction is accurate and leads to automatic liver volume calculation. We evaluate the accuracy of the estimated liver volumes with respect to CT segmentation volumes using RMSE. Our volume computation is statistically much closer to the volume estimated using CT scans than the volume computed using Childs' method by radiologists: p-value of 0.094 (>0.05) says that there is no significant difference between CT segmentation volumes and ours in contrast to Childs' method. We validate our method using investigations (ablation studies) on the US image resolution, the number of CT scans used for SSM, the number of principal components, and the number of input US scans. To the best of our knowledge, this is the first automatic liver volumetry system using a few incomplete US scans given a set of CT scans of livers for SSM.
format Preprint
id arxiv_https___arxiv_org_abs_2406_19336
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle LiverUSRecon: Automatic 3D Reconstruction and Volumetry of the Liver with a Few Partial Ultrasound Scans
Sivayogaraj, Kaushalya
Guruge, Sahan T.
Liyanage, Udari
Udupihille, Jeevani
Jayasinghe, Saroj
Fernando, Gerard
Rodrigo, Ranga
Liyanaarachchi, M. Rukshani
Image and Video Processing
Computer Vision and Pattern Recognition
3D reconstruction of the liver for volumetry is important for qualitative analysis and disease diagnosis. Liver volumetry using ultrasound (US) scans, although advantageous due to less acquisition time and safety, is challenging due to the inherent noisiness in US scans, blurry boundaries, and partial liver visibility. We address these challenges by using the segmentation masks of a few incomplete sagittal-plane US scans of the liver in conjunction with a statistical shape model (SSM) built using a set of CT scans of the liver. We compute the shape parameters needed to warp this canonical SSM to fit the US scans through a parametric regression network. The resulting 3D liver reconstruction is accurate and leads to automatic liver volume calculation. We evaluate the accuracy of the estimated liver volumes with respect to CT segmentation volumes using RMSE. Our volume computation is statistically much closer to the volume estimated using CT scans than the volume computed using Childs' method by radiologists: p-value of 0.094 (>0.05) says that there is no significant difference between CT segmentation volumes and ours in contrast to Childs' method. We validate our method using investigations (ablation studies) on the US image resolution, the number of CT scans used for SSM, the number of principal components, and the number of input US scans. To the best of our knowledge, this is the first automatic liver volumetry system using a few incomplete US scans given a set of CT scans of livers for SSM.
title LiverUSRecon: Automatic 3D Reconstruction and Volumetry of the Liver with a Few Partial Ultrasound Scans
topic Image and Video Processing
Computer Vision and Pattern Recognition
url https://arxiv.org/abs/2406.19336