Fault-Ride-Through (FRT) Control of a grid-connected Fixed-Speed Wind Energy Conversion System using STATCOM

Fuente: arXiv
Guardado en:
Detalles Bibliográficos
Autores principales: Olajube, Ayobami, Vedula, Satish, Omiloli, Koto, Anubi, Olugbenga
Formato: Preprint
Publicado: 2024
Materias:
Acceso en línea:
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
_version_ 1866916311658921984
author Olajube, Ayobami
Vedula, Satish
Omiloli, Koto
Anubi, Olugbenga
author_facet Olajube, Ayobami
Vedula, Satish
Omiloli, Koto
Anubi, Olugbenga
contents Wind energy conversion system (WECS) is stochastic in nature and has low inertia to grid voltage instability, poor reactive power compensation and most importantly fault susceptibility. Variable speed WECS such as a doubly-fed induction generators (DFIG) are well known to reach steady state quickly after fault occurrence without the need for an external reactive power source because of the presence of a back-to-back converter that provides independent control of the active and reactive power unlike in the fixed-speed squirrel cage induction generator (SCIG) counterpart that cant be stabilized unless ab external source of reactive power support is present. However, controlling DFIG is complicated and costly due to complete tripping unlike the fixed-speed generators which doesnt trip completely when fault occurs. Hence, in this work, a 48-pulse, 3-phase static synchronous compensator (STATCOM) is used to ensure reactive power compensation and fault-ride through (FRT) control of the SCIG against over-voltage emanating from fault occurrence in a grid-connected power system. The goal here is to guarantee voltage stability and fault-ride through control against injected faults within certain time ranges at the point of common coupling (PCC) between the AC sources, the load, and the fixed-speed WECS.
format Preprint
id arxiv_https___arxiv_org_abs_2407_03429
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle Fault-Ride-Through (FRT) Control of a grid-connected Fixed-Speed Wind Energy Conversion System using STATCOM
Olajube, Ayobami
Vedula, Satish
Omiloli, Koto
Anubi, Olugbenga
Optimization and Control
Wind energy conversion system (WECS) is stochastic in nature and has low inertia to grid voltage instability, poor reactive power compensation and most importantly fault susceptibility. Variable speed WECS such as a doubly-fed induction generators (DFIG) are well known to reach steady state quickly after fault occurrence without the need for an external reactive power source because of the presence of a back-to-back converter that provides independent control of the active and reactive power unlike in the fixed-speed squirrel cage induction generator (SCIG) counterpart that cant be stabilized unless ab external source of reactive power support is present. However, controlling DFIG is complicated and costly due to complete tripping unlike the fixed-speed generators which doesnt trip completely when fault occurs. Hence, in this work, a 48-pulse, 3-phase static synchronous compensator (STATCOM) is used to ensure reactive power compensation and fault-ride through (FRT) control of the SCIG against over-voltage emanating from fault occurrence in a grid-connected power system. The goal here is to guarantee voltage stability and fault-ride through control against injected faults within certain time ranges at the point of common coupling (PCC) between the AC sources, the load, and the fixed-speed WECS.
title Fault-Ride-Through (FRT) Control of a grid-connected Fixed-Speed Wind Energy Conversion System using STATCOM
topic Optimization and Control
url https://arxiv.org/abs/2407.03429