A Novel Portable and Wearable Broadband Near-Infrared Spectroscopy Device for In-Vivo Oxygenation and Metabolism Measurements

Fuente: arXiv
Saved in:
Bibliographic Details
Main Authors: Talati, Musa, Lange, Frederic, Airantzis, Dimitrios, Chitnis, Danial, Illukwe, Temisan, Gopal, Darshana, Pinti, Paola, Ranaei-Zamani, Niccole, Kowobari, Olayinka, Hillman, Sara, Siassakos, Dimitrios, David, Anna, Mitra, Subhabrata, Tachtsidis, Ilias
Format: Preprint
Published: 2024
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866910515123453952
author Talati, Musa
Lange, Frederic
Airantzis, Dimitrios
Chitnis, Danial
Illukwe, Temisan
Gopal, Darshana
Pinti, Paola
Ranaei-Zamani, Niccole
Kowobari, Olayinka
Hillman, Sara
Siassakos, Dimitrios
David, Anna
Mitra, Subhabrata
Tachtsidis, Ilias
author_facet Talati, Musa
Lange, Frederic
Airantzis, Dimitrios
Chitnis, Danial
Illukwe, Temisan
Gopal, Darshana
Pinti, Paola
Ranaei-Zamani, Niccole
Kowobari, Olayinka
Hillman, Sara
Siassakos, Dimitrios
David, Anna
Mitra, Subhabrata
Tachtsidis, Ilias
contents Broadband NIRS (bNIRS) is an extension of fNIRS that provides the same assessment of oxygenation biomarkers along with a valuable marker for oxygen metabolism at a cellular level, the oxidation state of cytochrome-c-oxidase (oxCCO). bNIRS implements many (100s) NIR wavelengths in the full NIR spectrum to address this and provide insight to tissue energetics. To supply these many wavelengths of light, broadband sources are required, and spectrometers are employed to distinguish power per wavelength. Current multi-channel bNIRS instruments are bulky and only semi-portable due to technological limitations. We propose a design for a bNIRS device that has been miniaturized to allow for portable use. This design leverages the innovations in photonic devices that have created a new line of microspectrometers and broadband NIR high-power LEDs; the Hamamatsu SMD-type spectrometer C14384MA and the Ushio SMBBIR45-1100 LED. This first-of-itskind device, referred to as microCYRIL (after its two predecessors CYRIL and miniCYRIL), has been developed for oxygenation and metabolism measurements with dual channel operation. To verify functionality, concentration changes in oxygenated (HbO2) and deoxygenated (HHb) haemoglobin and oxCCO were successfully tracked during a cuff-induced venous and arterial occlusion.
format Preprint
id arxiv_https___arxiv_org_abs_2407_04515
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle A Novel Portable and Wearable Broadband Near-Infrared Spectroscopy Device for In-Vivo Oxygenation and Metabolism Measurements
Talati, Musa
Lange, Frederic
Airantzis, Dimitrios
Chitnis, Danial
Illukwe, Temisan
Gopal, Darshana
Pinti, Paola
Ranaei-Zamani, Niccole
Kowobari, Olayinka
Hillman, Sara
Siassakos, Dimitrios
David, Anna
Mitra, Subhabrata
Tachtsidis, Ilias
Medical Physics
Broadband NIRS (bNIRS) is an extension of fNIRS that provides the same assessment of oxygenation biomarkers along with a valuable marker for oxygen metabolism at a cellular level, the oxidation state of cytochrome-c-oxidase (oxCCO). bNIRS implements many (100s) NIR wavelengths in the full NIR spectrum to address this and provide insight to tissue energetics. To supply these many wavelengths of light, broadband sources are required, and spectrometers are employed to distinguish power per wavelength. Current multi-channel bNIRS instruments are bulky and only semi-portable due to technological limitations. We propose a design for a bNIRS device that has been miniaturized to allow for portable use. This design leverages the innovations in photonic devices that have created a new line of microspectrometers and broadband NIR high-power LEDs; the Hamamatsu SMD-type spectrometer C14384MA and the Ushio SMBBIR45-1100 LED. This first-of-itskind device, referred to as microCYRIL (after its two predecessors CYRIL and miniCYRIL), has been developed for oxygenation and metabolism measurements with dual channel operation. To verify functionality, concentration changes in oxygenated (HbO2) and deoxygenated (HHb) haemoglobin and oxCCO were successfully tracked during a cuff-induced venous and arterial occlusion.
title A Novel Portable and Wearable Broadband Near-Infrared Spectroscopy Device for In-Vivo Oxygenation and Metabolism Measurements
topic Medical Physics
url https://arxiv.org/abs/2407.04515