Dynamical Embedding of Single Channel Electroencephalogram for Artifact Subspace Reconstruction

Fuente: arXiv
Guardado en:
Detalles Bibliográficos
Autores principales: Hazarika, Doli, KN, Vishnu, Ransing, Ramdas, Gupta, Cota Navin
Formato: Preprint
Publicado: 2024
Materias:
Acceso en línea:
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
_version_ 1866910676145930240
author Hazarika, Doli
KN, Vishnu
Ransing, Ramdas
Gupta, Cota Navin
author_facet Hazarika, Doli
KN, Vishnu
Ransing, Ramdas
Gupta, Cota Navin
contents This study introduces a novel framework to apply Artifact Subspace Reconstruction (ASR) algorithm on single-channel Electroencephalogram (EEG) data. ASR, renowned for its automated capability to effectively eliminate various artifacts like eye-blinks and eye movements from EEG signals. Importantly it has been implemented on android smartphones, but relied on multiple channels for principal component subspace calculations. To overcome this limitation, we incorporate the established dynamical embedding approach into the algorithm, naming it Embedded-ASR (E-ASR). In our proposed method, an embedded matrix is first constructed from a single-channel EEG data using series of delay vectors. ASR is then applied to this embedded matrix, and the resulting cleaned single-channel EEG is reconstructed by removing the time lag and concatenating the rows of the embedded matrix. Data was collected from four subjects in resting states with eyes open from pre-frontal (Fp1 and Fp2) electrodes using CameraEEG app. To assess the effectiveness of the E-ASR algorithm on an EEG dataset with artifacts, we employed performance metrics such as relative root mean square error (RRMSE), correlation coefficient (CC), average power ratio as well as estimated the number of eye-blinks with and without the E-ASR approach. E-ASR was able to reduce artifacts from the semi-simulated EEG data, with an RRMSE of 45.45% and a CC of 0.91. For real EEG data, the counted eye-blinks were manually cross-checked with ground truth obtained from CameraEEG video data across all subjects for individual Fp1 and Fp2 electrodes. In conclusion, our study suggests E-ASR framework can remove artifacts from single channel EEG data. This promising algorithm might have potential for smartphone-based natural environment EEG applications, where minimal number of electrodes is a critical factor.
format Preprint
id arxiv_https___arxiv_org_abs_2407_04727
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle Dynamical Embedding of Single Channel Electroencephalogram for Artifact Subspace Reconstruction
Hazarika, Doli
KN, Vishnu
Ransing, Ramdas
Gupta, Cota Navin
Signal Processing
This study introduces a novel framework to apply Artifact Subspace Reconstruction (ASR) algorithm on single-channel Electroencephalogram (EEG) data. ASR, renowned for its automated capability to effectively eliminate various artifacts like eye-blinks and eye movements from EEG signals. Importantly it has been implemented on android smartphones, but relied on multiple channels for principal component subspace calculations. To overcome this limitation, we incorporate the established dynamical embedding approach into the algorithm, naming it Embedded-ASR (E-ASR). In our proposed method, an embedded matrix is first constructed from a single-channel EEG data using series of delay vectors. ASR is then applied to this embedded matrix, and the resulting cleaned single-channel EEG is reconstructed by removing the time lag and concatenating the rows of the embedded matrix. Data was collected from four subjects in resting states with eyes open from pre-frontal (Fp1 and Fp2) electrodes using CameraEEG app. To assess the effectiveness of the E-ASR algorithm on an EEG dataset with artifacts, we employed performance metrics such as relative root mean square error (RRMSE), correlation coefficient (CC), average power ratio as well as estimated the number of eye-blinks with and without the E-ASR approach. E-ASR was able to reduce artifacts from the semi-simulated EEG data, with an RRMSE of 45.45% and a CC of 0.91. For real EEG data, the counted eye-blinks were manually cross-checked with ground truth obtained from CameraEEG video data across all subjects for individual Fp1 and Fp2 electrodes. In conclusion, our study suggests E-ASR framework can remove artifacts from single channel EEG data. This promising algorithm might have potential for smartphone-based natural environment EEG applications, where minimal number of electrodes is a critical factor.
title Dynamical Embedding of Single Channel Electroencephalogram for Artifact Subspace Reconstruction
topic Signal Processing
url https://arxiv.org/abs/2407.04727