Parameter Efficient Fine Tuning for Multi-scanner PET to PET Reconstruction

Fuente: arXiv
Salvato in:
Dettagli Bibliografici
Autori principali: Kim, Yumin, Choi, Gayoon, Hwang, Seong Jae
Natura: Preprint
Pubblicazione: 2024
Soggetti:
Accesso online:
Tags: Aggiungi Tag
Nessun Tag, puoi essere il primo ad aggiungerne!!
_version_ 1866913424754081792
author Kim, Yumin
Choi, Gayoon
Hwang, Seong Jae
author_facet Kim, Yumin
Choi, Gayoon
Hwang, Seong Jae
contents Reducing scan time in Positron Emission Tomography (PET) imaging while maintaining high-quality images is crucial for minimizing patient discomfort and radiation exposure. Due to the limited size of datasets and distribution discrepancy across scanners in medical imaging, fine-tuning in a parameter-efficient and effective manner is on the rise. Motivated by the potential of Parameter-Efficient Fine-Tuning (PEFT), we aim to address these issues by effectively leveraging PEFT to improve limited data and GPU resource issues in multi-scanner setups. In this paper, we introduce PETITE, Parameter-Efficient Fine-Tuning for MultI-scanner PET to PET REconstruction that uses fewer than 1% of the parameters. To the best of our knowledge, this study is the first to systematically explore the efficacy of diverse PEFT techniques in medical imaging reconstruction tasks via prevalent encoder-decoder-type deep models. This investigation, in particular, brings intriguing insights into PETITE as we show further improvements by treating encoder and decoder separately and mixing different PEFT methods, namely, Mix-PEFT. Using multi-scanner PET datasets comprised of five different scanners, we extensively test the cross-scanner PET scan time reduction performances (i.e., a model pre-trained on one scanner is fine-tuned on a different scanner) of 21 feasible Mix-PEFT combinations to derive optimal PETITE. We show that training with less than 1% parameters using PETITE performs on par with full fine-tuning (i.e., 100% parameter)
format Preprint
id arxiv_https___arxiv_org_abs_2407_07517
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle Parameter Efficient Fine Tuning for Multi-scanner PET to PET Reconstruction
Kim, Yumin
Choi, Gayoon
Hwang, Seong Jae
Image and Video Processing
Computer Vision and Pattern Recognition
Reducing scan time in Positron Emission Tomography (PET) imaging while maintaining high-quality images is crucial for minimizing patient discomfort and radiation exposure. Due to the limited size of datasets and distribution discrepancy across scanners in medical imaging, fine-tuning in a parameter-efficient and effective manner is on the rise. Motivated by the potential of Parameter-Efficient Fine-Tuning (PEFT), we aim to address these issues by effectively leveraging PEFT to improve limited data and GPU resource issues in multi-scanner setups. In this paper, we introduce PETITE, Parameter-Efficient Fine-Tuning for MultI-scanner PET to PET REconstruction that uses fewer than 1% of the parameters. To the best of our knowledge, this study is the first to systematically explore the efficacy of diverse PEFT techniques in medical imaging reconstruction tasks via prevalent encoder-decoder-type deep models. This investigation, in particular, brings intriguing insights into PETITE as we show further improvements by treating encoder and decoder separately and mixing different PEFT methods, namely, Mix-PEFT. Using multi-scanner PET datasets comprised of five different scanners, we extensively test the cross-scanner PET scan time reduction performances (i.e., a model pre-trained on one scanner is fine-tuned on a different scanner) of 21 feasible Mix-PEFT combinations to derive optimal PETITE. We show that training with less than 1% parameters using PETITE performs on par with full fine-tuning (i.e., 100% parameter)
title Parameter Efficient Fine Tuning for Multi-scanner PET to PET Reconstruction
topic Image and Video Processing
Computer Vision and Pattern Recognition
url https://arxiv.org/abs/2407.07517