Saved in:
Bibliographic Details
Main Authors: Savenkov, Savva, Svetlichnyi, Alexandr, Pshenichnov, Igor
Format: Preprint
Published: 2024
Subjects:
Online Access:https://arxiv.org/abs/2407.09851
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866909440701104128
author Savenkov, Savva
Svetlichnyi, Alexandr
Pshenichnov, Igor
author_facet Savenkov, Savva
Svetlichnyi, Alexandr
Pshenichnov, Igor
contents Single minibeams of protons, $^{4}$He, $^{12}$C and $^{16}$O in water were modeled with Geant4, and their dose distributions were parameterized with double-Gauss-Rutherford (DGR) functions. Dose distributions from arrays of 16 parallel minibeams centered on a rectangular or hexagonal grid were constructed from the parameterized minibeam profiles to simulate the lateral convergence of the minibeams resulting in a homogeneous dose field in the target tumor volume. Peak-to-valley dose ratios (PVDR) and dose-volume histograms (DVH) were calculated for the parameterized dose distributions and compared with those obtained directly from Geant4 modeling of minibeam arrays. The similarity of the results obtained by these two methods suggests that the fast calculation of dose profiles of minibeam arrays based on the DGR parameterizations proposed in this work can replace the time-consuming MC modeling in future preclinical studies and also in the development of treatment planning systems for minibeam therapy.
format Preprint
id arxiv_https___arxiv_org_abs_2407_09851
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle Parameterization of dose profiles of therapeutic minibeams of protons, $^{4}$He, $^{12}$C, and $^{16}$O
Savenkov, Savva
Svetlichnyi, Alexandr
Pshenichnov, Igor
Medical Physics
Single minibeams of protons, $^{4}$He, $^{12}$C and $^{16}$O in water were modeled with Geant4, and their dose distributions were parameterized with double-Gauss-Rutherford (DGR) functions. Dose distributions from arrays of 16 parallel minibeams centered on a rectangular or hexagonal grid were constructed from the parameterized minibeam profiles to simulate the lateral convergence of the minibeams resulting in a homogeneous dose field in the target tumor volume. Peak-to-valley dose ratios (PVDR) and dose-volume histograms (DVH) were calculated for the parameterized dose distributions and compared with those obtained directly from Geant4 modeling of minibeam arrays. The similarity of the results obtained by these two methods suggests that the fast calculation of dose profiles of minibeam arrays based on the DGR parameterizations proposed in this work can replace the time-consuming MC modeling in future preclinical studies and also in the development of treatment planning systems for minibeam therapy.
title Parameterization of dose profiles of therapeutic minibeams of protons, $^{4}$He, $^{12}$C, and $^{16}$O
topic Medical Physics
url https://arxiv.org/abs/2407.09851