Results for pixel and strip centimeter-scale AC-LGAD sensors with a 120 GeV proton beam

Fuente: arXiv
Enregistré dans:
Détails bibliographiques
Auteurs principaux: Dutta, Irene, Madrid, Christopher, Heller, Ryan, Nanda, Shirsendu, Shekar, Danush, Martín, Claudio San, Barría, Matías, Apresyan, Artur, Ye, Zhenyu, Brooks, William K., Chen, Wei, D'Amen, Gabriele, Giacomini, Gabriele, Tricoli, Alessandro, Hayrapetyan, Aram, Lee, Hakseong, Köseyan, Ohannes Kamer, Los, Sergey, Nakamura, Koji, Kita, Sayuka, Imamura, Tomoka, Peña, Cristían, Xie, Si
Format: Preprint
Publié: 2024
Sujets:
Accès en ligne:
Tags: Ajouter un tag
Pas de tags, Soyez le premier à ajouter un tag!
_version_ 1866913657738231808
author Dutta, Irene
Madrid, Christopher
Heller, Ryan
Nanda, Shirsendu
Shekar, Danush
Martín, Claudio San
Barría, Matías
Apresyan, Artur
Ye, Zhenyu
Brooks, William K.
Chen, Wei
D'Amen, Gabriele
Giacomini, Gabriele
Tricoli, Alessandro
Hayrapetyan, Aram
Lee, Hakseong
Köseyan, Ohannes Kamer
Los, Sergey
Nakamura, Koji
Kita, Sayuka
Imamura, Tomoka
Peña, Cristían
Xie, Si
author_facet Dutta, Irene
Madrid, Christopher
Heller, Ryan
Nanda, Shirsendu
Shekar, Danush
Martín, Claudio San
Barría, Matías
Apresyan, Artur
Ye, Zhenyu
Brooks, William K.
Chen, Wei
D'Amen, Gabriele
Giacomini, Gabriele
Tricoli, Alessandro
Hayrapetyan, Aram
Lee, Hakseong
Köseyan, Ohannes Kamer
Los, Sergey
Nakamura, Koji
Kita, Sayuka
Imamura, Tomoka
Peña, Cristían
Xie, Si
contents We present the results of an extensive evaluation of strip and pixel AC-LGAD sensors tested with a 120 GeV proton beam, focusing on the influence of design parameters on the sensor temporal and spatial resolutions. Results show that reducing the thickness of pixel sensors significantly enhances their time resolution, with 20 $μ$m-thick sensors achieving around 20 ps. Uniform performance is attainable with optimized sheet resistance, making these sensors ideal for future timing detectors. Conversely, 20 $μ$m-thick strip sensors exhibit higher jitter than similar pixel sensors, negatively impacting time resolution, despite reduced Landau fluctuations with respect to the 50 $μ$m-thick versions. Additionally, it is observed that a low resistivity in strip sensors limits signal size and time resolution, whereas higher resistivity improves performance. This study highlights the importance of tuning the n$^{+}$ sheet resistance and suggests that further improvements should target specific applications like the Electron-Ion Collider or other future collider experiments. In addition, the detailed performance of four AC-LGADs sensor designs is reported as examples of possible candidates for specific detector applications. These advancements position AC-LGADs as promising candidates for future 4D tracking systems, pending the development of specialized readout electronics.
format Preprint
id arxiv_https___arxiv_org_abs_2407_09928
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle Results for pixel and strip centimeter-scale AC-LGAD sensors with a 120 GeV proton beam
Dutta, Irene
Madrid, Christopher
Heller, Ryan
Nanda, Shirsendu
Shekar, Danush
Martín, Claudio San
Barría, Matías
Apresyan, Artur
Ye, Zhenyu
Brooks, William K.
Chen, Wei
D'Amen, Gabriele
Giacomini, Gabriele
Tricoli, Alessandro
Hayrapetyan, Aram
Lee, Hakseong
Köseyan, Ohannes Kamer
Los, Sergey
Nakamura, Koji
Kita, Sayuka
Imamura, Tomoka
Peña, Cristían
Xie, Si
Instrumentation and Detectors
High Energy Physics - Experiment
We present the results of an extensive evaluation of strip and pixel AC-LGAD sensors tested with a 120 GeV proton beam, focusing on the influence of design parameters on the sensor temporal and spatial resolutions. Results show that reducing the thickness of pixel sensors significantly enhances their time resolution, with 20 $μ$m-thick sensors achieving around 20 ps. Uniform performance is attainable with optimized sheet resistance, making these sensors ideal for future timing detectors. Conversely, 20 $μ$m-thick strip sensors exhibit higher jitter than similar pixel sensors, negatively impacting time resolution, despite reduced Landau fluctuations with respect to the 50 $μ$m-thick versions. Additionally, it is observed that a low resistivity in strip sensors limits signal size and time resolution, whereas higher resistivity improves performance. This study highlights the importance of tuning the n$^{+}$ sheet resistance and suggests that further improvements should target specific applications like the Electron-Ion Collider or other future collider experiments. In addition, the detailed performance of four AC-LGADs sensor designs is reported as examples of possible candidates for specific detector applications. These advancements position AC-LGADs as promising candidates for future 4D tracking systems, pending the development of specialized readout electronics.
title Results for pixel and strip centimeter-scale AC-LGAD sensors with a 120 GeV proton beam
topic Instrumentation and Detectors
High Energy Physics - Experiment
url https://arxiv.org/abs/2407.09928