_version_ 1866909420199346176
author Lisowska, M.
Aleksan, R.
Angelis, Y.
Aune, S.
Bortfeldt, J.
Brunbauer, F.
Brunoldi, M.
Chatzianagnostou, E.
Datta, J.
Dehmelt, K.
Fanourakis, G.
Ferry, S.
Fiorina, D.
Floethner, K. J.
Gallinaro, M.
Garcia, F.
Giomataris, I.
Gnanvo, K.
Iguaz, F. J.
Janssens, D.
Kallitsopoulou, A.
Kovacic, M.
Kross, B.
Lai, C. C.
Legou, P.
Liu, J.
Lupberger, M.
Maniatis, I.
McKisson, J.
Meng, Y.
Muller, H.
De Oliveira, R.
Oliveri, E.
Orlandini, G.
Pandey, A.
Papaevangelou, T.
Pomorski, M.
Robert, M.
Ropelewski, L.
Sampsonidis, D.
Scharenberg, L.
Schneider, T.
Scorsone, E.
Sohl, L.
van Stenis, M.
Tsipolitis, Y.
Tzamarias, S.
Utrobicic, A.
Vai, I.
Veenhof, R.
Viezzi, L.
Vitulo, P.
Volpato, C.
Wang, X.
White, S.
Xi, W.
Zhang, Z.
Zhou, Y.
author_facet Lisowska, M.
Aleksan, R.
Angelis, Y.
Aune, S.
Bortfeldt, J.
Brunbauer, F.
Brunoldi, M.
Chatzianagnostou, E.
Datta, J.
Dehmelt, K.
Fanourakis, G.
Ferry, S.
Fiorina, D.
Floethner, K. J.
Gallinaro, M.
Garcia, F.
Giomataris, I.
Gnanvo, K.
Iguaz, F. J.
Janssens, D.
Kallitsopoulou, A.
Kovacic, M.
Kross, B.
Lai, C. C.
Legou, P.
Liu, J.
Lupberger, M.
Maniatis, I.
McKisson, J.
Meng, Y.
Muller, H.
De Oliveira, R.
Oliveri, E.
Orlandini, G.
Pandey, A.
Papaevangelou, T.
Pomorski, M.
Robert, M.
Ropelewski, L.
Sampsonidis, D.
Scharenberg, L.
Schneider, T.
Scorsone, E.
Sohl, L.
van Stenis, M.
Tsipolitis, Y.
Tzamarias, S.
Utrobicic, A.
Vai, I.
Veenhof, R.
Viezzi, L.
Vitulo, P.
Volpato, C.
Wang, X.
White, S.
Xi, W.
Zhang, Z.
Zhou, Y.
contents The PICOSEC Micromegas detector is a~precise-timing gaseous detector based on a~Cherenkov radiator coupled with a~semi-transparent photocathode and a~Micromegas amplifying structure, targeting a~time resolution of tens of picoseconds for minimum ionising particles. Initial single-pad prototypes have demonstrated a~time resolution below 25 ps, prompting ongoing developments to adapt the concept for High Energy Physics applications, where sub-nanosecond precision is essential for event separation, improved track reconstruction and particle identification. The achieved performance is being transferred to robust multi-channel detector modules suitable for large-area detection systems requiring excellent timing precision. To enhance the robustness and stability of the PICOSEC Micromegas detector, research on robust carbon-based photocathodes, including Diamond-Like Carbon (DLC) and Boron Carbide (B4C), is pursued. Results from prototypes equipped with DLC and B4C photocathodes exhibited a~time resolution of approximately 32 ps and 34.5 ps, respectively. Efforts dedicated to improve detector robustness and stability enhance the feasibility of the PICOSEC Micromegas concept for large experiments, ensuring sustained performance while maintaining excellent timing precision.
format Preprint
id arxiv_https___arxiv_org_abs_2407_09953
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle Photocathode characterisation for robust PICOSEC Micromegas precise-timing detectors
Lisowska, M.
Aleksan, R.
Angelis, Y.
Aune, S.
Bortfeldt, J.
Brunbauer, F.
Brunoldi, M.
Chatzianagnostou, E.
Datta, J.
Dehmelt, K.
Fanourakis, G.
Ferry, S.
Fiorina, D.
Floethner, K. J.
Gallinaro, M.
Garcia, F.
Giomataris, I.
Gnanvo, K.
Iguaz, F. J.
Janssens, D.
Kallitsopoulou, A.
Kovacic, M.
Kross, B.
Lai, C. C.
Legou, P.
Liu, J.
Lupberger, M.
Maniatis, I.
McKisson, J.
Meng, Y.
Muller, H.
De Oliveira, R.
Oliveri, E.
Orlandini, G.
Pandey, A.
Papaevangelou, T.
Pomorski, M.
Robert, M.
Ropelewski, L.
Sampsonidis, D.
Scharenberg, L.
Schneider, T.
Scorsone, E.
Sohl, L.
van Stenis, M.
Tsipolitis, Y.
Tzamarias, S.
Utrobicic, A.
Vai, I.
Veenhof, R.
Viezzi, L.
Vitulo, P.
Volpato, C.
Wang, X.
White, S.
Xi, W.
Zhang, Z.
Zhou, Y.
Instrumentation and Detectors
The PICOSEC Micromegas detector is a~precise-timing gaseous detector based on a~Cherenkov radiator coupled with a~semi-transparent photocathode and a~Micromegas amplifying structure, targeting a~time resolution of tens of picoseconds for minimum ionising particles. Initial single-pad prototypes have demonstrated a~time resolution below 25 ps, prompting ongoing developments to adapt the concept for High Energy Physics applications, where sub-nanosecond precision is essential for event separation, improved track reconstruction and particle identification. The achieved performance is being transferred to robust multi-channel detector modules suitable for large-area detection systems requiring excellent timing precision. To enhance the robustness and stability of the PICOSEC Micromegas detector, research on robust carbon-based photocathodes, including Diamond-Like Carbon (DLC) and Boron Carbide (B4C), is pursued. Results from prototypes equipped with DLC and B4C photocathodes exhibited a~time resolution of approximately 32 ps and 34.5 ps, respectively. Efforts dedicated to improve detector robustness and stability enhance the feasibility of the PICOSEC Micromegas concept for large experiments, ensuring sustained performance while maintaining excellent timing precision.
title Photocathode characterisation for robust PICOSEC Micromegas precise-timing detectors
topic Instrumentation and Detectors
url https://arxiv.org/abs/2407.09953