Design and optimization of a hadronic calorimeter based on micropattern gaseous detectors for a future experiment at the Muon Collider
Fuente:
arXiv
Salvato in:
| Autori principali: | , , , , , , , , , , , , , , , , |
|---|---|
| Natura: | Preprint |
| Pubblicazione: |
2024
|
| Soggetti: | |
| Accesso online: | |
| Tags: |
Aggiungi Tag
Nessun Tag, puoi essere il primo ad aggiungerne!!
|
| _version_ | 1866911955181109248 |
|---|---|
| author | Pellecchia, Antonello Buonsante, Marco Borysova, Maryna Colaleo, Anna Camerlingo, Maria Teresa Longo, Luigi Iodice, Mauro Maggi, Marcello Moleri, Luca Radogna, Raffaella Sekhniaidze, Givi Simone, Federica Maria Stamerra, Anna Venditti, Rosamaria Verwilligen, Piet Zavazieva, Darina Zaza, Angela |
| author_facet | Pellecchia, Antonello Buonsante, Marco Borysova, Maryna Colaleo, Anna Camerlingo, Maria Teresa Longo, Luigi Iodice, Mauro Maggi, Marcello Moleri, Luca Radogna, Raffaella Sekhniaidze, Givi Simone, Federica Maria Stamerra, Anna Venditti, Rosamaria Verwilligen, Piet Zavazieva, Darina Zaza, Angela |
| contents | Micro-pattern gaseous detectors (MPGDs) are a promising readout technology for hadronic calorimeters (HCAL) thanks to their good space resolution, longevity and rate capability. We describe the development of a HCAL based on MPGDs for an experiment at the proposed Muon Collider. The design of a semi-digital MPGD-HCAL is shown and its performance is calculated with Monte Carlo simulations with high-energy pions, showing an energy resolution down to 8\% for \SI{80}{\giga\eV} pions. We also present the performance of twelve MPGD prototypes with different technologies (MicroMegas, $μ$-RWELL and RPWELL) assembled and operated in test beam first with high-energy muons and later with pions in a hadronic calorimeter prototype of $\sim1\,λ_\text{I}$ length; the detectors have a good response uniformity (lower than 17\%) and space resolution and their performance in the calorimeter shows very good agreement with the Monte Carlo shower calculation. |
| format | Preprint |
| id |
arxiv_https___arxiv_org_abs_2407_10261 |
| institution | arXiv |
| publishDate | 2024 |
| record_format | arxiv |
| spellingShingle | Design and optimization of a hadronic calorimeter based on micropattern gaseous detectors for a future experiment at the Muon Collider Pellecchia, Antonello Buonsante, Marco Borysova, Maryna Colaleo, Anna Camerlingo, Maria Teresa Longo, Luigi Iodice, Mauro Maggi, Marcello Moleri, Luca Radogna, Raffaella Sekhniaidze, Givi Simone, Federica Maria Stamerra, Anna Venditti, Rosamaria Verwilligen, Piet Zavazieva, Darina Zaza, Angela Instrumentation and Detectors Micro-pattern gaseous detectors (MPGDs) are a promising readout technology for hadronic calorimeters (HCAL) thanks to their good space resolution, longevity and rate capability. We describe the development of a HCAL based on MPGDs for an experiment at the proposed Muon Collider. The design of a semi-digital MPGD-HCAL is shown and its performance is calculated with Monte Carlo simulations with high-energy pions, showing an energy resolution down to 8\% for \SI{80}{\giga\eV} pions. We also present the performance of twelve MPGD prototypes with different technologies (MicroMegas, $μ$-RWELL and RPWELL) assembled and operated in test beam first with high-energy muons and later with pions in a hadronic calorimeter prototype of $\sim1\,λ_\text{I}$ length; the detectors have a good response uniformity (lower than 17\%) and space resolution and their performance in the calorimeter shows very good agreement with the Monte Carlo shower calculation. |
| title | Design and optimization of a hadronic calorimeter based on micropattern gaseous detectors for a future experiment at the Muon Collider |
| topic | Instrumentation and Detectors |
| url | https://arxiv.org/abs/2407.10261 |