Harnessing an elastic flow instability to improve the kinetic performance of chromatographic columns

Fuente: arXiv
Guardado en:
Detalles Bibliográficos
Autores principales: Gritti, Fabrice, Chen, Emily Y., Datta, Sujit S.
Formato: Preprint
Publicado: 2024
Materias:
Acceso en línea:
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
_version_ 1866929421985775616
author Gritti, Fabrice
Chen, Emily Y.
Datta, Sujit S.
author_facet Gritti, Fabrice
Chen, Emily Y.
Datta, Sujit S.
contents Despite decades of research and development, the optimal efficiency of slurry-packed HPLC columns is still hindered by inherent long-range flow heterogeneity from the wall to the central bulk region of these columns. Here, we show an example of how this issue can be addressed through the straightforward addition of a semidilute amount (500~ppm) of a large, flexible, synthetic polymer (18~MDa partially hydrolyzed polyacrylamide, HPAM) to the mobile phase (1\% NaCl aqueous solution) during operation of a 4.6 mm $\times$ 300 mm column packed with 10~$μ$m BEH$^{\mathrm{TM}}$ 125~Å\ Particles. Addition of the polymer imparts elasticity to the mobile phase, causing the flow in the interparticle pore space to become unstable above a threshold flow rate. We verify the development of this elastic flow instability using pressure drop measurements of the friction factor versus Reynolds number. In prior work, we showed that this flow instability is characterized by large spatiotemporal fluctuations in the pore-scale flow velocities that may promote analyte dispersion across the column. Axial dispersion measurements of the quasi non-retained tracer thiourea confirm this possibility: they unequivocally reveal that operating above the onset of the instability improves column efficiency by significantly reducing peak asymmetry. These experiments thereby provide a proof-of-concept demonstration that elastic flow instabilities can be harnessed to mitigate the negative impact of trans-column flow heterogeneities on the efficiency of slurry-packed HPLC columns. While this approach has its own inherent limitations and constraints, our work lays the groundwork for future targeted development of polymers that can impart elasticity when dissolved in commonly used liquid chromatography mobile phases, and can thereby generate elastic flow instabilities to help improve the resolution of HPLC columns.
format Preprint
id arxiv_https___arxiv_org_abs_2407_11311
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle Harnessing an elastic flow instability to improve the kinetic performance of chromatographic columns
Gritti, Fabrice
Chen, Emily Y.
Datta, Sujit S.
Fluid Dynamics
Soft Condensed Matter
Chaotic Dynamics
Applied Physics
Despite decades of research and development, the optimal efficiency of slurry-packed HPLC columns is still hindered by inherent long-range flow heterogeneity from the wall to the central bulk region of these columns. Here, we show an example of how this issue can be addressed through the straightforward addition of a semidilute amount (500~ppm) of a large, flexible, synthetic polymer (18~MDa partially hydrolyzed polyacrylamide, HPAM) to the mobile phase (1\% NaCl aqueous solution) during operation of a 4.6 mm $\times$ 300 mm column packed with 10~$μ$m BEH$^{\mathrm{TM}}$ 125~Å\ Particles. Addition of the polymer imparts elasticity to the mobile phase, causing the flow in the interparticle pore space to become unstable above a threshold flow rate. We verify the development of this elastic flow instability using pressure drop measurements of the friction factor versus Reynolds number. In prior work, we showed that this flow instability is characterized by large spatiotemporal fluctuations in the pore-scale flow velocities that may promote analyte dispersion across the column. Axial dispersion measurements of the quasi non-retained tracer thiourea confirm this possibility: they unequivocally reveal that operating above the onset of the instability improves column efficiency by significantly reducing peak asymmetry. These experiments thereby provide a proof-of-concept demonstration that elastic flow instabilities can be harnessed to mitigate the negative impact of trans-column flow heterogeneities on the efficiency of slurry-packed HPLC columns. While this approach has its own inherent limitations and constraints, our work lays the groundwork for future targeted development of polymers that can impart elasticity when dissolved in commonly used liquid chromatography mobile phases, and can thereby generate elastic flow instabilities to help improve the resolution of HPLC columns.
title Harnessing an elastic flow instability to improve the kinetic performance of chromatographic columns
topic Fluid Dynamics
Soft Condensed Matter
Chaotic Dynamics
Applied Physics
url https://arxiv.org/abs/2407.11311