On the E-DeltaE low pressure pentane filled detection module of DGFRS-2 setup

Fuente: arXiv
Guardado en:
Detalles Bibliográficos
Autores principales: Ibadullayev, D., Polyakov, A. N., Tsyganov, Yu. S., Voinov, A. A., Shumeiko, M. V.
Formato: Preprint
Publicado: 2024
Materias:
Acceso en línea:
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
_version_ 1866911958116073472
author Ibadullayev, D.
Polyakov, A. N.
Tsyganov, Yu. S.
Voinov, A. A.
Shumeiko, M. V.
author_facet Ibadullayev, D.
Polyakov, A. N.
Tsyganov, Yu. S.
Voinov, A. A.
Shumeiko, M. V.
contents The paper describes a new E-Delta-E detection module which includes a position-sensitive double-sided strip detector (DSSD) and a low-pressure pentane-filled Delta-E chamber for detection of Evaporation Residues (ER) in complete fusion nuclear reactions. The goal is to synthesize superheavy isotopes at the new DC-280 (Dubna Cyclotron) cyclotron of the Joint Institute for Nuclear Research (JINR). With the 48Ca ion beam intensity of about 5-7 pmcA (particle micro ampere) and the Delta-E counter count rate of approximately 1.0E+4 sec-1, we observe a decrease in the overall registration efficiency of the gas Delta-E counter. The paper proposes a solution to this problem: introduction of an additional negatively biased electrode, which results in the stabilization of the Delta-E detector operation.
format Preprint
id arxiv_https___arxiv_org_abs_2407_12418
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle On the E-DeltaE low pressure pentane filled detection module of DGFRS-2 setup
Ibadullayev, D.
Polyakov, A. N.
Tsyganov, Yu. S.
Voinov, A. A.
Shumeiko, M. V.
Instrumentation and Detectors
Nuclear Experiment
The paper describes a new E-Delta-E detection module which includes a position-sensitive double-sided strip detector (DSSD) and a low-pressure pentane-filled Delta-E chamber for detection of Evaporation Residues (ER) in complete fusion nuclear reactions. The goal is to synthesize superheavy isotopes at the new DC-280 (Dubna Cyclotron) cyclotron of the Joint Institute for Nuclear Research (JINR). With the 48Ca ion beam intensity of about 5-7 pmcA (particle micro ampere) and the Delta-E counter count rate of approximately 1.0E+4 sec-1, we observe a decrease in the overall registration efficiency of the gas Delta-E counter. The paper proposes a solution to this problem: introduction of an additional negatively biased electrode, which results in the stabilization of the Delta-E detector operation.
title On the E-DeltaE low pressure pentane filled detection module of DGFRS-2 setup
topic Instrumentation and Detectors
Nuclear Experiment
url https://arxiv.org/abs/2407.12418