Phase-Imaging Ion-Cyclotron-Resonance Mass Spectrometry with the Canadian Penning Trap at CARIBU
Fuente:
arXiv
Salvato in:
| Autori principali: | , , , , , , , , , , , |
|---|---|
| Natura: | Preprint |
| Pubblicazione: |
2024
|
| Soggetti: | |
| Accesso online: | |
| Tags: |
Aggiungi Tag
Nessun Tag, puoi essere il primo ad aggiungerne!!
|
| _version_ | 1866915260508667904 |
|---|---|
| author | Ray, D. Valverde, A. A. Brodeur, M. Buchinger, F. Clark, J. A. Liu, B. Morgan, G. E. Orford, R. Porter, W. S. Savard, G. Sharma, K. S. Yan, X. L. |
| author_facet | Ray, D. Valverde, A. A. Brodeur, M. Buchinger, F. Clark, J. A. Liu, B. Morgan, G. E. Orford, R. Porter, W. S. Savard, G. Sharma, K. S. Yan, X. L. |
| contents | The Canadian Penning Trap mass spectrometer (CPT) has conducted precision mass measurements of neutron-rich nuclides from the CAlifornium Rare Isotope Breeder Upgrade (CARIBU) of the Argonne Tandem Linac Accelerator System (ATLAS) facility at Argonne National Laboratory using the Phase-Imaging Ion-Cyclotron-Resonance (PIICR) technique for over half a decade. Here we discuss the CPT system, and methods to improve accuracy and precision in mass measurement using PI-ICR including some optimization techniques and recently studied systematic effects. |
| format | Preprint |
| id |
arxiv_https___arxiv_org_abs_2407_13802 |
| institution | arXiv |
| publishDate | 2024 |
| record_format | arxiv |
| spellingShingle | Phase-Imaging Ion-Cyclotron-Resonance Mass Spectrometry with the Canadian Penning Trap at CARIBU Ray, D. Valverde, A. A. Brodeur, M. Buchinger, F. Clark, J. A. Liu, B. Morgan, G. E. Orford, R. Porter, W. S. Savard, G. Sharma, K. S. Yan, X. L. Instrumentation and Detectors Nuclear Experiment The Canadian Penning Trap mass spectrometer (CPT) has conducted precision mass measurements of neutron-rich nuclides from the CAlifornium Rare Isotope Breeder Upgrade (CARIBU) of the Argonne Tandem Linac Accelerator System (ATLAS) facility at Argonne National Laboratory using the Phase-Imaging Ion-Cyclotron-Resonance (PIICR) technique for over half a decade. Here we discuss the CPT system, and methods to improve accuracy and precision in mass measurement using PI-ICR including some optimization techniques and recently studied systematic effects. |
| title | Phase-Imaging Ion-Cyclotron-Resonance Mass Spectrometry with the Canadian Penning Trap at CARIBU |
| topic | Instrumentation and Detectors Nuclear Experiment |
| url | https://arxiv.org/abs/2407.13802 |