3D-printed axicon enables extended depth-of-focus intravascular optical coherence tomography

Fuente: arXiv
Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Ruchka, Pavel, Kushwaha, Alok, Marathe, Jessica A., Xiang, Lei, Chen, Rouyan, Kirk, Rodney, Tan, Joanne T. M., Bursill, Christina A., Verjans, Johan, Thiele, Simon, Fitridge, Robert, McLaughlin, Robert A., Psaltis, Peter J., Giessen, Harald, Li, Jiawen
Format: Preprint
Veröffentlicht: 2024
Schlagworte:
Online-Zugang:
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
_version_ 1866913439238062080
author Ruchka, Pavel
Kushwaha, Alok
Marathe, Jessica A.
Xiang, Lei
Chen, Rouyan
Kirk, Rodney
Tan, Joanne T. M.
Bursill, Christina A.
Verjans, Johan
Thiele, Simon
Fitridge, Robert
McLaughlin, Robert A.
Psaltis, Peter J.
Giessen, Harald
Li, Jiawen
author_facet Ruchka, Pavel
Kushwaha, Alok
Marathe, Jessica A.
Xiang, Lei
Chen, Rouyan
Kirk, Rodney
Tan, Joanne T. M.
Bursill, Christina A.
Verjans, Johan
Thiele, Simon
Fitridge, Robert
McLaughlin, Robert A.
Psaltis, Peter J.
Giessen, Harald
Li, Jiawen
contents A fundamental challenge in endoscopy is how to fabricate a small fiber-optic probe that can achieve comparable function to probes with large, complicated optics (e.g., high resolution and extended depth of focus). To achieve high resolution over an extended depth of focus (DOF), the application of needle-like beams has been proposed. However, existing methods using miniaturized needle beam designs fail to adequately correct astigmatism and other monochromatic aberrations, limiting the resolution of at least one axis. Here, we describe a novel approach to realize freeform beam-shaping endoscopic probes via two-photon direct laser writing, also known as micro 3D-printing. We present a design achieving approximately 8-micron resolution with a DOF of >0.8 mm at a central wavelength of 1310 nm. The probe has a diameter of 0.25 mm (without the catheter sheaths) and is fabricated using a single printing step directly on the optical fiber. We demonstrate our device in intravascular imaging of living atherosclerotic pigs at multiple time points, as well as human arteries with plaques ex vivo. This is the first step to enable beam-tailoring endoscopic probes which achieve diffraction-limited resolution over a large DOF.
format Preprint
id arxiv_https___arxiv_org_abs_2407_14825
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle 3D-printed axicon enables extended depth-of-focus intravascular optical coherence tomography
Ruchka, Pavel
Kushwaha, Alok
Marathe, Jessica A.
Xiang, Lei
Chen, Rouyan
Kirk, Rodney
Tan, Joanne T. M.
Bursill, Christina A.
Verjans, Johan
Thiele, Simon
Fitridge, Robert
McLaughlin, Robert A.
Psaltis, Peter J.
Giessen, Harald
Li, Jiawen
Optics
Biological Physics
Medical Physics
A fundamental challenge in endoscopy is how to fabricate a small fiber-optic probe that can achieve comparable function to probes with large, complicated optics (e.g., high resolution and extended depth of focus). To achieve high resolution over an extended depth of focus (DOF), the application of needle-like beams has been proposed. However, existing methods using miniaturized needle beam designs fail to adequately correct astigmatism and other monochromatic aberrations, limiting the resolution of at least one axis. Here, we describe a novel approach to realize freeform beam-shaping endoscopic probes via two-photon direct laser writing, also known as micro 3D-printing. We present a design achieving approximately 8-micron resolution with a DOF of >0.8 mm at a central wavelength of 1310 nm. The probe has a diameter of 0.25 mm (without the catheter sheaths) and is fabricated using a single printing step directly on the optical fiber. We demonstrate our device in intravascular imaging of living atherosclerotic pigs at multiple time points, as well as human arteries with plaques ex vivo. This is the first step to enable beam-tailoring endoscopic probes which achieve diffraction-limited resolution over a large DOF.
title 3D-printed axicon enables extended depth-of-focus intravascular optical coherence tomography
topic Optics
Biological Physics
Medical Physics
url https://arxiv.org/abs/2407.14825