Clinical Validation of myOSLchip system for Radiotherapy Dosimetry

Fuente: arXiv
Saved in:
Bibliographic Details
Main Authors: Davis, H., Siebers, J., Wijesooriya, K., Mistro, M.
Format: Preprint
Published: 2024
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866911963779432448
author Davis, H.
Siebers, J.
Wijesooriya, K.
Mistro, M.
author_facet Davis, H.
Siebers, J.
Wijesooriya, K.
Mistro, M.
contents In radiation oncology, inter-fractional dosimetry is often performed with luminescent dosimeters to verify the accurate delivery of a plan and ensure patient safety. Optically stimulated luminescent detectors (OSLDs) are the most commonly used detector type which offers good dose linearity and accuracy in the megavoltage energy range. Freiberg Instruments offer a dosimetry system under the brand name myOLSchip which consists of a BeO OSL dosimeter, reader, and eraser. A Varian Truebeam was used to characterize the detectors and calibrate their response in order to perform in-situ dosimetry during treatment. The OSLDs were tested with both photon and electron beams from 6-15 MV and 6-20 MV respectively. The dose signal to dose conversion in this investigation follows the recommendations of TG-191 in developing a dose response curve and creating a batch calibration factor for each dosimeter. The repeatability of this system is also investigated following successive erasing and re-irradiation cycles. The results of this data have been compared to the stated accuracy and precision of the BeO detectors by the manufacturer and shown to have good dose linearity and repeatability across multiple exposures and erasure cycles.
format Preprint
id arxiv_https___arxiv_org_abs_2407_15246
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle Clinical Validation of myOSLchip system for Radiotherapy Dosimetry
Davis, H.
Siebers, J.
Wijesooriya, K.
Mistro, M.
Medical Physics
In radiation oncology, inter-fractional dosimetry is often performed with luminescent dosimeters to verify the accurate delivery of a plan and ensure patient safety. Optically stimulated luminescent detectors (OSLDs) are the most commonly used detector type which offers good dose linearity and accuracy in the megavoltage energy range. Freiberg Instruments offer a dosimetry system under the brand name myOLSchip which consists of a BeO OSL dosimeter, reader, and eraser. A Varian Truebeam was used to characterize the detectors and calibrate their response in order to perform in-situ dosimetry during treatment. The OSLDs were tested with both photon and electron beams from 6-15 MV and 6-20 MV respectively. The dose signal to dose conversion in this investigation follows the recommendations of TG-191 in developing a dose response curve and creating a batch calibration factor for each dosimeter. The repeatability of this system is also investigated following successive erasing and re-irradiation cycles. The results of this data have been compared to the stated accuracy and precision of the BeO detectors by the manufacturer and shown to have good dose linearity and repeatability across multiple exposures and erasure cycles.
title Clinical Validation of myOSLchip system for Radiotherapy Dosimetry
topic Medical Physics
url https://arxiv.org/abs/2407.15246