Spatial resolution studies using point spread function extraction in optically read out Micromegas and GEM detectors

Fuente: arXiv
Salvato in:
Dettagli Bibliografici
Autori principali: Cools, A., Ferrer-Ribas, E., Papaevangelou, T., Pollacco, E. C., Lisowska, M., Brunbauer, F. M., Oliveri, E., Iguaz, F. J.
Natura: Preprint
Pubblicazione: 2024
Soggetti:
Accesso online:
Tags: Aggiungi Tag
Nessun Tag, puoi essere il primo ad aggiungerne!!
_version_ 1866914880849707008
author Cools, A.
Ferrer-Ribas, E.
Papaevangelou, T.
Pollacco, E. C.
Lisowska, M.
Brunbauer, F. M.
Oliveri, E.
Iguaz, F. J.
author_facet Cools, A.
Ferrer-Ribas, E.
Papaevangelou, T.
Pollacco, E. C.
Lisowska, M.
Brunbauer, F. M.
Oliveri, E.
Iguaz, F. J.
contents Optically read out gaseous detectors are used in track reconstruction and imaging applications requiring high granularity images. Among resolution-determining factors, the amplification stage plays a crucial role and optimisations of detector geometry are pursued to maximise spatial resolution. To compare MicroPattern Gaseous Detector (MPGD) technologies, focused low-energy X-ray beams at the SOLEIL synchrotron facility were used to record and extract point spread function widths with Micromegas and GEM detectors. Point spread function width of $\approx$108\,\microns for Micromegas and $\approx$127\,\microns for GEM foils were extracted. The scanning of the beam with different intensities, energies and across the detector active region can be used to quantify resolution-limiting factors and improve imaging detectors using MPGD amplification stages.
format Preprint
id arxiv_https___arxiv_org_abs_2407_15491
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle Spatial resolution studies using point spread function extraction in optically read out Micromegas and GEM detectors
Cools, A.
Ferrer-Ribas, E.
Papaevangelou, T.
Pollacco, E. C.
Lisowska, M.
Brunbauer, F. M.
Oliveri, E.
Iguaz, F. J.
Instrumentation and Detectors
Optically read out gaseous detectors are used in track reconstruction and imaging applications requiring high granularity images. Among resolution-determining factors, the amplification stage plays a crucial role and optimisations of detector geometry are pursued to maximise spatial resolution. To compare MicroPattern Gaseous Detector (MPGD) technologies, focused low-energy X-ray beams at the SOLEIL synchrotron facility were used to record and extract point spread function widths with Micromegas and GEM detectors. Point spread function width of $\approx$108\,\microns for Micromegas and $\approx$127\,\microns for GEM foils were extracted. The scanning of the beam with different intensities, energies and across the detector active region can be used to quantify resolution-limiting factors and improve imaging detectors using MPGD amplification stages.
title Spatial resolution studies using point spread function extraction in optically read out Micromegas and GEM detectors
topic Instrumentation and Detectors
url https://arxiv.org/abs/2407.15491