Demonstrating sub-electron noise performance in Single electron Sensitive Readout (SiSeRO) devices

Fuente: arXiv
Enregistré dans:
Détails bibliographiques
Auteurs principaux: Chattopadhyay, Tanmoy, Herrmann, Sven, Orel, Peter, Donlon, Kevan, Allen, Steven W., Bautz, Marshall W., Cantrall, Brianna, Cooper, Michael, LaMarr, Beverly, Leitz, Chris, Miller, Eric, Morris, R. Glenn, Pan, Abigail Y., Prigozhin, Gregory, Prigozhin, Ilya, Stueber, Haley R., Wilkins, Daniel R.
Format: Preprint
Publié: 2024
Sujets:
Accès en ligne:
Tags: Ajouter un tag
Pas de tags, Soyez le premier à ajouter un tag!
_version_ 1866909265642389504
author Chattopadhyay, Tanmoy
Herrmann, Sven
Orel, Peter
Donlon, Kevan
Allen, Steven W.
Bautz, Marshall W.
Cantrall, Brianna
Cooper, Michael
LaMarr, Beverly
Leitz, Chris
Miller, Eric
Morris, R. Glenn
Pan, Abigail Y.
Prigozhin, Gregory
Prigozhin, Ilya
Stueber, Haley R.
Wilkins, Daniel R.
author_facet Chattopadhyay, Tanmoy
Herrmann, Sven
Orel, Peter
Donlon, Kevan
Allen, Steven W.
Bautz, Marshall W.
Cantrall, Brianna
Cooper, Michael
LaMarr, Beverly
Leitz, Chris
Miller, Eric
Morris, R. Glenn
Pan, Abigail Y.
Prigozhin, Gregory
Prigozhin, Ilya
Stueber, Haley R.
Wilkins, Daniel R.
contents Single electron Sensitive Read Out (SiSeRO) is a novel on-chip charge detection technology that can, in principle, provide significantly greater responsivity and improved noise performance than traditional charge coupled device (CCD) readout circuitry. The SiSeRO, developed by MIT Lincoln Laboratory, uses a p-MOSFET transistor with a depleted back-gate region under the transistor channel; as charge is transferred into the back gate region, the transistor current is modulated. With our first generation SiSeRO devices, we previously achieved a responsivity of around 800 pA per electron, an equivalent noise charge (ENC) of 4.5 electrons root mean square (RMS), and a full width at half maximum (FWHM) spectral resolution of 130 eV at 5.9 keV, at a readout speed of 625 Kpixel/s and for a detector temperature of 250 K. Importantly, since the charge signal remains unaffected by the SiSeRO readout process, we have also been able to implement Repetitive Non-Destructive Readout (RNDR), achieving an improved ENC performance. In this paper, we demonstrate sub-electron noise sensitivity with these devices, utilizing an enhanced test setup optimized for RNDR measurements, with excellent temperature control, improved readout circuitry, and advanced digital filtering techniques. We are currently fabricating new SiSeRO detectors with more sensitive and RNDR-optimized amplifier designs, which will help mature the SiSeRO technology in the future and eventually lead to the pathway to develop active pixel sensor (APS) arrays using sensitive SiSeRO amplifiers on each pixel. Active pixel devices with sub-electron sensitivity and fast readout present an exciting option for next generation, large area astronomical X-ray telescopes requiring fast, low-noise megapixel imagers.
format Preprint
id arxiv_https___arxiv_org_abs_2407_16754
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle Demonstrating sub-electron noise performance in Single electron Sensitive Readout (SiSeRO) devices
Chattopadhyay, Tanmoy
Herrmann, Sven
Orel, Peter
Donlon, Kevan
Allen, Steven W.
Bautz, Marshall W.
Cantrall, Brianna
Cooper, Michael
LaMarr, Beverly
Leitz, Chris
Miller, Eric
Morris, R. Glenn
Pan, Abigail Y.
Prigozhin, Gregory
Prigozhin, Ilya
Stueber, Haley R.
Wilkins, Daniel R.
Instrumentation and Methods for Astrophysics
High Energy Astrophysical Phenomena
Instrumentation and Detectors
Single electron Sensitive Read Out (SiSeRO) is a novel on-chip charge detection technology that can, in principle, provide significantly greater responsivity and improved noise performance than traditional charge coupled device (CCD) readout circuitry. The SiSeRO, developed by MIT Lincoln Laboratory, uses a p-MOSFET transistor with a depleted back-gate region under the transistor channel; as charge is transferred into the back gate region, the transistor current is modulated. With our first generation SiSeRO devices, we previously achieved a responsivity of around 800 pA per electron, an equivalent noise charge (ENC) of 4.5 electrons root mean square (RMS), and a full width at half maximum (FWHM) spectral resolution of 130 eV at 5.9 keV, at a readout speed of 625 Kpixel/s and for a detector temperature of 250 K. Importantly, since the charge signal remains unaffected by the SiSeRO readout process, we have also been able to implement Repetitive Non-Destructive Readout (RNDR), achieving an improved ENC performance. In this paper, we demonstrate sub-electron noise sensitivity with these devices, utilizing an enhanced test setup optimized for RNDR measurements, with excellent temperature control, improved readout circuitry, and advanced digital filtering techniques. We are currently fabricating new SiSeRO detectors with more sensitive and RNDR-optimized amplifier designs, which will help mature the SiSeRO technology in the future and eventually lead to the pathway to develop active pixel sensor (APS) arrays using sensitive SiSeRO amplifiers on each pixel. Active pixel devices with sub-electron sensitivity and fast readout present an exciting option for next generation, large area astronomical X-ray telescopes requiring fast, low-noise megapixel imagers.
title Demonstrating sub-electron noise performance in Single electron Sensitive Readout (SiSeRO) devices
topic Instrumentation and Methods for Astrophysics
High Energy Astrophysical Phenomena
Instrumentation and Detectors
url https://arxiv.org/abs/2407.16754