SOXS NIR: Optomechanical integration and alignment, optical performance verification before full instrument assembly

Fuente: arXiv
Guardado en:
Detalles Bibliográficos
Autores principales: Genoni, M., Aliverti, M., Pariani, G., Oggioni, L., Vitali, F., D'Alessio, F., D'Avanzo, P., Campana, S., Munari, M., Sanchez, R. Zanmar, Scaudo, A., Landoni, M., Young, D., Scuderi, S., Schipani, P., Riva, M., Claudi, R., Radhakrishnan, K., Battaini, F., Rubin, A., Baruffolo, A., Capasso, G., Cosentino, R., Hershko, O., Kuncarayakti, H., Pignata, G., Ben-Ami, S., Brucalassi, A., Achren, J., Araiza-Duran, J. A., Arcavi, I., Asquini, L., Bruch, R., Cappellaro, E., Colapietro, M., Della Valle, M., De Pascale, M., Di Benedetto, R., D'Orsi, S., Gal-Yam, A., Diaz, M. Hernandez, Kotilainen, J., Causi, G. Li, Marty, L., Mattila, S., Rappaport, M., Ricci, D., Salasnich, B., Smartt, S., Stritzinger, M., Ventura, H.
Formato: Preprint
Publicado: 2024
Materias:
Acceso en línea:
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
_version_ 1866910540301860864
author Genoni, M.
Aliverti, M.
Pariani, G.
Oggioni, L.
Vitali, F.
D'Alessio, F.
D'Avanzo, P.
Campana, S.
Munari, M.
Sanchez, R. Zanmar
Scaudo, A.
Landoni, M.
Young, D.
Scuderi, S.
Schipani, P.
Riva, M.
Claudi, R.
Radhakrishnan, K.
Battaini, F.
Rubin, A.
Baruffolo, A.
Capasso, G.
Cosentino, R.
Hershko, O.
Kuncarayakti, H.
Pignata, G.
Ben-Ami, S.
Brucalassi, A.
Achren, J.
Araiza-Duran, J. A.
Arcavi, I.
Asquini, L.
Bruch, R.
Cappellaro, E.
Colapietro, M.
Della Valle, M.
De Pascale, M.
Di Benedetto, R.
D'Orsi, S.
Gal-Yam, A.
Diaz, M. Hernandez
Kotilainen, J.
Causi, G. Li
Marty, L.
Mattila, S.
Rappaport, M.
Ricci, D.
Salasnich, B.
Smartt, S.
Stritzinger, M.
Ventura, H.
author_facet Genoni, M.
Aliverti, M.
Pariani, G.
Oggioni, L.
Vitali, F.
D'Alessio, F.
D'Avanzo, P.
Campana, S.
Munari, M.
Sanchez, R. Zanmar
Scaudo, A.
Landoni, M.
Young, D.
Scuderi, S.
Schipani, P.
Riva, M.
Claudi, R.
Radhakrishnan, K.
Battaini, F.
Rubin, A.
Baruffolo, A.
Capasso, G.
Cosentino, R.
Hershko, O.
Kuncarayakti, H.
Pignata, G.
Ben-Ami, S.
Brucalassi, A.
Achren, J.
Araiza-Duran, J. A.
Arcavi, I.
Asquini, L.
Bruch, R.
Cappellaro, E.
Colapietro, M.
Della Valle, M.
De Pascale, M.
Di Benedetto, R.
D'Orsi, S.
Gal-Yam, A.
Diaz, M. Hernandez
Kotilainen, J.
Causi, G. Li
Marty, L.
Mattila, S.
Rappaport, M.
Ricci, D.
Salasnich, B.
Smartt, S.
Stritzinger, M.
Ventura, H.
contents This paper presents the opto-mechanical integration and alignment, functional and optical performance verification of the NIR arm of Son Of X-Shooter (SOXS) instrument. SOXS will be a single object spectroscopic facility for the ESO-NTT 3.6-m telescope, made by two arms high efficiency spectrographs, able to cover the spectral range 350 2050 nm with a mean resolving power R~4500. In particular the NIR arm is a cryogenic echelle cross-dispersed spectrograph spanning the 780-2050 nm range. We describe the integration and alignment method performed to assemble the different opto-mechanical elements and their installation on the NIR vacuum vessel, which mostly relies on mechanical characterization. The tests done to assess the image quality, linear dispersion and orders trace in laboratory conditions are summarized. The full optical performance verification, namely echellogram format, image quality and resulting spectral resolving power in the whole NIR arm (optical path and science detector) is detailed. Such verification is one of the most relevant prerequisites for the subsequent full instrument assembly and provisional acceptance in Europe milestone, foreseen in 2024.
format Preprint
id arxiv_https___arxiv_org_abs_2407_17244
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle SOXS NIR: Optomechanical integration and alignment, optical performance verification before full instrument assembly
Genoni, M.
Aliverti, M.
Pariani, G.
Oggioni, L.
Vitali, F.
D'Alessio, F.
D'Avanzo, P.
Campana, S.
Munari, M.
Sanchez, R. Zanmar
Scaudo, A.
Landoni, M.
Young, D.
Scuderi, S.
Schipani, P.
Riva, M.
Claudi, R.
Radhakrishnan, K.
Battaini, F.
Rubin, A.
Baruffolo, A.
Capasso, G.
Cosentino, R.
Hershko, O.
Kuncarayakti, H.
Pignata, G.
Ben-Ami, S.
Brucalassi, A.
Achren, J.
Araiza-Duran, J. A.
Arcavi, I.
Asquini, L.
Bruch, R.
Cappellaro, E.
Colapietro, M.
Della Valle, M.
De Pascale, M.
Di Benedetto, R.
D'Orsi, S.
Gal-Yam, A.
Diaz, M. Hernandez
Kotilainen, J.
Causi, G. Li
Marty, L.
Mattila, S.
Rappaport, M.
Ricci, D.
Salasnich, B.
Smartt, S.
Stritzinger, M.
Ventura, H.
Instrumentation and Methods for Astrophysics
This paper presents the opto-mechanical integration and alignment, functional and optical performance verification of the NIR arm of Son Of X-Shooter (SOXS) instrument. SOXS will be a single object spectroscopic facility for the ESO-NTT 3.6-m telescope, made by two arms high efficiency spectrographs, able to cover the spectral range 350 2050 nm with a mean resolving power R~4500. In particular the NIR arm is a cryogenic echelle cross-dispersed spectrograph spanning the 780-2050 nm range. We describe the integration and alignment method performed to assemble the different opto-mechanical elements and their installation on the NIR vacuum vessel, which mostly relies on mechanical characterization. The tests done to assess the image quality, linear dispersion and orders trace in laboratory conditions are summarized. The full optical performance verification, namely echellogram format, image quality and resulting spectral resolving power in the whole NIR arm (optical path and science detector) is detailed. Such verification is one of the most relevant prerequisites for the subsequent full instrument assembly and provisional acceptance in Europe milestone, foreseen in 2024.
title SOXS NIR: Optomechanical integration and alignment, optical performance verification before full instrument assembly
topic Instrumentation and Methods for Astrophysics
url https://arxiv.org/abs/2407.17244