Pre-processing and quality control of large clinical CT head datasets for intracranial arterial calcification segmentation

Fuente: arXiv
Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Jin, Benjamin, Hernández, Maria del C. Valdés, Fontanella, Alessandro, Li, Wenwen, Platt, Eleanor, Armitage, Paul, Storkey, Amos, Wardlaw, Joanna M., Mair, Grant
Format: Preprint
Veröffentlicht: 2024
Schlagworte:
Online-Zugang:
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
_version_ 1866918079667109888
author Jin, Benjamin
Hernández, Maria del C. Valdés
Fontanella, Alessandro
Li, Wenwen
Platt, Eleanor
Armitage, Paul
Storkey, Amos
Wardlaw, Joanna M.
Mair, Grant
author_facet Jin, Benjamin
Hernández, Maria del C. Valdés
Fontanella, Alessandro
Li, Wenwen
Platt, Eleanor
Armitage, Paul
Storkey, Amos
Wardlaw, Joanna M.
Mair, Grant
contents As a potential non-invasive biomarker for ischaemic stroke, intracranial arterial calcification (IAC) could be used for stroke risk assessment on CT head scans routinely acquired for other reasons (e.g. trauma, confusion). Artificial intelligence methods can support IAC scoring, but they have not yet been developed for clinical imaging. Large heterogeneous clinical CT datasets are necessary for the training of such methods, but they exhibit expected and unexpected data anomalies. Using CTs from a large clinical trial, the third International Stroke Trial (IST-3), we propose a pipeline that uses as input non-enhanced CT scans to output regions of interest capturing selected large intracranial arteries for IAC scoring. Our method uses co-registration with templates. We focus on quality control, using information presence along the z-axis of the imaging to group and apply similarity measures (structural similarity index measure) to triage assessment of individual image series. Additionally, we propose superimposing thresholded binary masks of the series to inspect large quantities of data in parallel. We identify and exclude unrecoverable samples and registration failures. In total, our pipeline processes 10,659 CT series, rejecting 4,322 (41%) in the entire process, 1,450 (14% of the total) during quality control, and outputting 6,337 series. Our pipeline enables effective and efficient region of interest localisation for targeted IAC segmentation.
format Preprint
id arxiv_https___arxiv_org_abs_2408_01199
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle Pre-processing and quality control of large clinical CT head datasets for intracranial arterial calcification segmentation
Jin, Benjamin
Hernández, Maria del C. Valdés
Fontanella, Alessandro
Li, Wenwen
Platt, Eleanor
Armitage, Paul
Storkey, Amos
Wardlaw, Joanna M.
Mair, Grant
Image and Video Processing
As a potential non-invasive biomarker for ischaemic stroke, intracranial arterial calcification (IAC) could be used for stroke risk assessment on CT head scans routinely acquired for other reasons (e.g. trauma, confusion). Artificial intelligence methods can support IAC scoring, but they have not yet been developed for clinical imaging. Large heterogeneous clinical CT datasets are necessary for the training of such methods, but they exhibit expected and unexpected data anomalies. Using CTs from a large clinical trial, the third International Stroke Trial (IST-3), we propose a pipeline that uses as input non-enhanced CT scans to output regions of interest capturing selected large intracranial arteries for IAC scoring. Our method uses co-registration with templates. We focus on quality control, using information presence along the z-axis of the imaging to group and apply similarity measures (structural similarity index measure) to triage assessment of individual image series. Additionally, we propose superimposing thresholded binary masks of the series to inspect large quantities of data in parallel. We identify and exclude unrecoverable samples and registration failures. In total, our pipeline processes 10,659 CT series, rejecting 4,322 (41%) in the entire process, 1,450 (14% of the total) during quality control, and outputting 6,337 series. Our pipeline enables effective and efficient region of interest localisation for targeted IAC segmentation.
title Pre-processing and quality control of large clinical CT head datasets for intracranial arterial calcification segmentation
topic Image and Video Processing
url https://arxiv.org/abs/2408.01199