contents We investigate the fundamental and practical precision limits of thermometry in bosonic and fermionic environments by coupling an $N$-level probe to them and continuously monitoring it. Our findings show that the ultimate precision limit, quantified by the Fisher information, scales linearly with $N$, offering an exponential improvement over equilibrium thermometry, where the scaling is only $\log^2 N$. For a fixed Hamiltonian structure, we develop a maximum likelihood estimation strategy that maps the observed continuously monitored trajectories of the probe into temperature estimates with minimal error. By optimizing over all possible Hamiltonian structures, we discover that the optimal configuration is an effective two-level system, with both levels exhibiting degeneracy that increases with $N$-a stark contrast to equilibrium thermometry, where the ground state remains non-degenerate. Our results have practical implications. First, continuous monitoring is experimentally feasible on several platforms and accounts for the preparation time of the probe, which is often overlooked in other approaches such as prepare-and-reset. Second, the linear scaling is robust against deviations from the effective two-level structure of the optimal Hamiltonian. Additionally, this robustness extends to cases of initial ignorance about the temperature. Thus, in global estimation problems, the linear scaling remains intact even without adaptive strategies.
format Preprint
id arxiv_https___arxiv_org_abs_2408_01313
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle Optimal limits of continuously monitored thermometers and their Hamiltonian structure
Mehboudi, Mohammad
Meier, Florian
Huber, Marcus
Miller, Harry J. D.
Quantum Physics
We investigate the fundamental and practical precision limits of thermometry in bosonic and fermionic environments by coupling an $N$-level probe to them and continuously monitoring it. Our findings show that the ultimate precision limit, quantified by the Fisher information, scales linearly with $N$, offering an exponential improvement over equilibrium thermometry, where the scaling is only $\log^2 N$. For a fixed Hamiltonian structure, we develop a maximum likelihood estimation strategy that maps the observed continuously monitored trajectories of the probe into temperature estimates with minimal error. By optimizing over all possible Hamiltonian structures, we discover that the optimal configuration is an effective two-level system, with both levels exhibiting degeneracy that increases with $N$-a stark contrast to equilibrium thermometry, where the ground state remains non-degenerate. Our results have practical implications. First, continuous monitoring is experimentally feasible on several platforms and accounts for the preparation time of the probe, which is often overlooked in other approaches such as prepare-and-reset. Second, the linear scaling is robust against deviations from the effective two-level structure of the optimal Hamiltonian. Additionally, this robustness extends to cases of initial ignorance about the temperature. Thus, in global estimation problems, the linear scaling remains intact even without adaptive strategies.
title Optimal limits of continuously monitored thermometers and their Hamiltonian structure
topic Quantum Physics
url https://arxiv.org/abs/2408.01313