QuSpin Zero-Field Magnetometer Characterization for the TUCAN Experiment
Fuente:
arXiv
Salvato in:
| Autori principali: | , , |
|---|---|
| Natura: | Preprint |
| Pubblicazione: |
2024
|
| Soggetti: | |
| Accesso online: | |
| Tags: |
Aggiungi Tag
Nessun Tag, puoi essere il primo ad aggiungerne!!
|
| _version_ | 1866929547304239104 |
|---|---|
| author | Zhao, Michael Mammei, Russell Fujimoto, Derek |
| author_facet | Zhao, Michael Mammei, Russell Fujimoto, Derek |
| contents | The TUCAN nEDM experiment characterizes the QuSpin Zero-Field Magnetometer (QZFM) to accurately map residual fields within a large magnetically shielded room. The magnetometer's intrinsic offset was measured to be within 3 nT and stable over a period of one year. The response was shown to be within 2 percent of linearity in the zero-field regime, up to 2 nTpp, and then follows a smooth dispersion curve. Crosstalk effects induced by multisensor operation were determined to have a small effect, and inconsequential with a separation above 6 cm. These results enable the QZFM for accurate measurement of DC fields, increase the operational range of QZFM by a factor of more than an order of magnitude, and allow for higher efficiency and flexibility by green-lighting simultaneous operation of multiple QZFMs. |
| format | Preprint |
| id |
arxiv_https___arxiv_org_abs_2408_02941 |
| institution | arXiv |
| publishDate | 2024 |
| record_format | arxiv |
| spellingShingle | QuSpin Zero-Field Magnetometer Characterization for the TUCAN Experiment Zhao, Michael Mammei, Russell Fujimoto, Derek Instrumentation and Detectors The TUCAN nEDM experiment characterizes the QuSpin Zero-Field Magnetometer (QZFM) to accurately map residual fields within a large magnetically shielded room. The magnetometer's intrinsic offset was measured to be within 3 nT and stable over a period of one year. The response was shown to be within 2 percent of linearity in the zero-field regime, up to 2 nTpp, and then follows a smooth dispersion curve. Crosstalk effects induced by multisensor operation were determined to have a small effect, and inconsequential with a separation above 6 cm. These results enable the QZFM for accurate measurement of DC fields, increase the operational range of QZFM by a factor of more than an order of magnitude, and allow for higher efficiency and flexibility by green-lighting simultaneous operation of multiple QZFMs. |
| title | QuSpin Zero-Field Magnetometer Characterization for the TUCAN Experiment |
| topic | Instrumentation and Detectors |
| url | https://arxiv.org/abs/2408.02941 |