Enhancing Material Screening at Boulby Underground Laboratory with XIA UltraLo-1800 Alpha Particle Detectors

Fuente: arXiv
Guardado en:
Detalles Bibliográficos
Autores principales: Maouloud, Sid El Moctar Ahmed, Nguyen, Anh, Liu, XinRan, Dobson, James Edward Young, Ghag, Chamkaur, Floch, Léna Le, Meehan, Emma, Murphy, Alexander St. John, Paling, Sean Michael, Saakyan, Ruben, Scovell, Paul Robert, Toth, Christopher
Formato: Preprint
Publicado: 2024
Materias:
Acceso en línea:
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
_version_ 1866915174419529728
author Maouloud, Sid El Moctar Ahmed
Nguyen, Anh
Liu, XinRan
Dobson, James Edward Young
Ghag, Chamkaur
Floch, Léna Le
Meehan, Emma
Murphy, Alexander St. John
Paling, Sean Michael
Saakyan, Ruben
Scovell, Paul Robert
Toth, Christopher
author_facet Maouloud, Sid El Moctar Ahmed
Nguyen, Anh
Liu, XinRan
Dobson, James Edward Young
Ghag, Chamkaur
Floch, Léna Le
Meehan, Emma
Murphy, Alexander St. John
Paling, Sean Michael
Saakyan, Ruben
Scovell, Paul Robert
Toth, Christopher
contents The Boulby UnderGround Screening (BUGS) facility, located at the Boulby Underground Laboratory, has significantly advanced its material screening capabilities by installing two XIA UltraLo-1800 alpha particle detectors. This study presents a comprehensive evaluation of one of these detectors, operated 1,100 meters underground at the Boulby Underground Laboratory, which provides significant shielding from cosmic radiation and maintains a low ambient radon activity of 2.30 $\pm$ 0.03 Bq/m$^3$. Our evaluation focuses on energy reconstruction accuracy, background radiation rates, and operational stability. The XIA UltraLo-1800 detector demonstrates remarkable stability in energy reconstruction, with less than 0.1 MeV variation over four years. Moreover, the implementation of a graphite-filled PTFE liner in the sample tray resulted in a significant reduction in background radiation levels compared to measurements with the original stainless steel tray, achieving an average activity of 0.15 $\pm$ 0.01 $α$/cm$^2$/khr. Copper sample assays, performed before and after radon exposure, demonstrated the detector's ability to accurately identify and quantify $^{210}$Po contamination. By implementing the robust cleanliness procedures and protocols described in this article, we observed a reduction in $^{210}$Po activity from 0.504 $\pm$ 0.022 mBq to 0.336 $\pm$ 0.013 mBq, highlighting the crucial role of refined cleaning methods in minimizing background for sensitive experiments. Additionally, observations of elevated background activity levels post-high-activity sample measurements illustrate the need for careful management of assay conditions and environment to maintain low background levels. These results highlight the potential of the XIA UltraLo-1800 in enhancing the precision of material assays essential for reducing background interference in rare event experiments.
format Preprint
id arxiv_https___arxiv_org_abs_2408_06925
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle Enhancing Material Screening at Boulby Underground Laboratory with XIA UltraLo-1800 Alpha Particle Detectors
Maouloud, Sid El Moctar Ahmed
Nguyen, Anh
Liu, XinRan
Dobson, James Edward Young
Ghag, Chamkaur
Floch, Léna Le
Meehan, Emma
Murphy, Alexander St. John
Paling, Sean Michael
Saakyan, Ruben
Scovell, Paul Robert
Toth, Christopher
Instrumentation and Detectors
The Boulby UnderGround Screening (BUGS) facility, located at the Boulby Underground Laboratory, has significantly advanced its material screening capabilities by installing two XIA UltraLo-1800 alpha particle detectors. This study presents a comprehensive evaluation of one of these detectors, operated 1,100 meters underground at the Boulby Underground Laboratory, which provides significant shielding from cosmic radiation and maintains a low ambient radon activity of 2.30 $\pm$ 0.03 Bq/m$^3$. Our evaluation focuses on energy reconstruction accuracy, background radiation rates, and operational stability. The XIA UltraLo-1800 detector demonstrates remarkable stability in energy reconstruction, with less than 0.1 MeV variation over four years. Moreover, the implementation of a graphite-filled PTFE liner in the sample tray resulted in a significant reduction in background radiation levels compared to measurements with the original stainless steel tray, achieving an average activity of 0.15 $\pm$ 0.01 $α$/cm$^2$/khr. Copper sample assays, performed before and after radon exposure, demonstrated the detector's ability to accurately identify and quantify $^{210}$Po contamination. By implementing the robust cleanliness procedures and protocols described in this article, we observed a reduction in $^{210}$Po activity from 0.504 $\pm$ 0.022 mBq to 0.336 $\pm$ 0.013 mBq, highlighting the crucial role of refined cleaning methods in minimizing background for sensitive experiments. Additionally, observations of elevated background activity levels post-high-activity sample measurements illustrate the need for careful management of assay conditions and environment to maintain low background levels. These results highlight the potential of the XIA UltraLo-1800 in enhancing the precision of material assays essential for reducing background interference in rare event experiments.
title Enhancing Material Screening at Boulby Underground Laboratory with XIA UltraLo-1800 Alpha Particle Detectors
topic Instrumentation and Detectors
url https://arxiv.org/abs/2408.06925