Optically pumped vector magnetometer using a strong bias magnetic field

Fuente: arXiv
Guardado en:
Detalles Bibliográficos
Autores principales: Schönau, Thomas, Scholtes, Theo, Wittkämper, Florian, Sekels, Alexander, Hiebel, Stefan, Oelsner, Gregor, Stolz, Ronny
Formato: Preprint
Publicado: 2024
Materias:
Acceso en línea:
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
_version_ 1866914915835445248
author Schönau, Thomas
Scholtes, Theo
Wittkämper, Florian
Sekels, Alexander
Hiebel, Stefan
Oelsner, Gregor
Stolz, Ronny
author_facet Schönau, Thomas
Scholtes, Theo
Wittkämper, Florian
Sekels, Alexander
Hiebel, Stefan
Oelsner, Gregor
Stolz, Ronny
contents We present a novel approach allowing an optically pumped magnetometer (OPM) to be operated within Earth's magnetic field as a vector magnetometer whose sensitive axis can be freely defined. This approach enables the measurement of any vector component of the Earth's magnetic field with the same sensitivity. The OPM is realized by a microfabricated cesium vapor cell with nitrogen buffer gas, which is immersed into a homogeneous bias field of about 730 $\mathrm{μT}$. Since this bias field is about one order of magnitude stronger than Earth's magnetic field, it defines the sensitive axis of the OPM. The bias field is generated by solid-state magnets and was designed to exhibit a very low relative inhomogeneity ($< 10^{-4}$ in relative units) within the vapor cell dimensions as well as a point of vanishing temperature dependence at around 40°C. The OPM utilizes the light narrowing effect, which enables effective suppression of spin-exchange relaxation even in such large magnetic field amplitude. Based on this implementation, we demonstrate a white noise floor of below 60 $\mathrm{fT/\sqrt{Hz}}$ in the interval between 100 Hz and 600 Hz and a sensor bandwidth of $> 2$ kHz. Our approach enables unshielded ultrasensitive vectorial measurement capabilities relevant in many important applications.
format Preprint
id arxiv_https___arxiv_org_abs_2408_09915
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle Optically pumped vector magnetometer using a strong bias magnetic field
Schönau, Thomas
Scholtes, Theo
Wittkämper, Florian
Sekels, Alexander
Hiebel, Stefan
Oelsner, Gregor
Stolz, Ronny
Instrumentation and Detectors
Atomic Physics
Geophysics
We present a novel approach allowing an optically pumped magnetometer (OPM) to be operated within Earth's magnetic field as a vector magnetometer whose sensitive axis can be freely defined. This approach enables the measurement of any vector component of the Earth's magnetic field with the same sensitivity. The OPM is realized by a microfabricated cesium vapor cell with nitrogen buffer gas, which is immersed into a homogeneous bias field of about 730 $\mathrm{μT}$. Since this bias field is about one order of magnitude stronger than Earth's magnetic field, it defines the sensitive axis of the OPM. The bias field is generated by solid-state magnets and was designed to exhibit a very low relative inhomogeneity ($< 10^{-4}$ in relative units) within the vapor cell dimensions as well as a point of vanishing temperature dependence at around 40°C. The OPM utilizes the light narrowing effect, which enables effective suppression of spin-exchange relaxation even in such large magnetic field amplitude. Based on this implementation, we demonstrate a white noise floor of below 60 $\mathrm{fT/\sqrt{Hz}}$ in the interval between 100 Hz and 600 Hz and a sensor bandwidth of $> 2$ kHz. Our approach enables unshielded ultrasensitive vectorial measurement capabilities relevant in many important applications.
title Optically pumped vector magnetometer using a strong bias magnetic field
topic Instrumentation and Detectors
Atomic Physics
Geophysics
url https://arxiv.org/abs/2408.09915