Low-vibration cryogenic test facility for next generation of ground-based gravitational-wave observatories

Fuente: arXiv
Salvato in:
Dettagli Bibliografici
Autori principali: Kapasi, D. P., McRae, T. G., Eichholz, J., Altin, P. A., McClelland, D. E., Slagmolen, B. J. J.
Natura: Preprint
Pubblicazione: 2024
Soggetti:
Accesso online:
Tags: Aggiungi Tag
Nessun Tag, puoi essere il primo ad aggiungerne!!
_version_ 1866918131415384064
author Kapasi, D. P.
McRae, T. G.
Eichholz, J.
Altin, P. A.
McClelland, D. E.
Slagmolen, B. J. J.
author_facet Kapasi, D. P.
McRae, T. G.
Eichholz, J.
Altin, P. A.
McClelland, D. E.
Slagmolen, B. J. J.
contents We present the design and commissioning of a cryogenic low-vibration test facility that measures displacement noise from a gram-scale silicon cantilever at the level of 10$^{-16}\, \mathrm{m/\sqrt{Hz}}$ at 1kHz. A volume of $\sim$36 litres is enclosed by radiation shields cooling an optical test cavity that is suspended from a multi-stage pendulum chain providing isolation from acoustic and environmental noise. This 3kg test cavity housing a crystalline silicon cantilever is radiatively cooled to 123K in 41 hours and held at that temperature over many months with a relative temperature stability of $\pm$1mK. The facility is capable of interferometrically measuring temperature-dependent broadband displacement noise between 50Hz and 10kHz where current and future ground-based gravitational wave observatories are most sensitive. With suitable cantilever design, the cryogenic facility we describe here will allow for the measurement of broadband thermal noise in crystalline silicon at 123K. This will guide the design of suspensions in planned future cryogenic ground-based gravitational-wave detectors such as LIGO Voyager and the Einstein Telescope. This facility is also suitable for the testing of new mirror coatings at cryogenic temperatures.
format Preprint
id arxiv_https___arxiv_org_abs_2408_10477
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle Low-vibration cryogenic test facility for next generation of ground-based gravitational-wave observatories
Kapasi, D. P.
McRae, T. G.
Eichholz, J.
Altin, P. A.
McClelland, D. E.
Slagmolen, B. J. J.
Instrumentation and Detectors
We present the design and commissioning of a cryogenic low-vibration test facility that measures displacement noise from a gram-scale silicon cantilever at the level of 10$^{-16}\, \mathrm{m/\sqrt{Hz}}$ at 1kHz. A volume of $\sim$36 litres is enclosed by radiation shields cooling an optical test cavity that is suspended from a multi-stage pendulum chain providing isolation from acoustic and environmental noise. This 3kg test cavity housing a crystalline silicon cantilever is radiatively cooled to 123K in 41 hours and held at that temperature over many months with a relative temperature stability of $\pm$1mK. The facility is capable of interferometrically measuring temperature-dependent broadband displacement noise between 50Hz and 10kHz where current and future ground-based gravitational wave observatories are most sensitive. With suitable cantilever design, the cryogenic facility we describe here will allow for the measurement of broadband thermal noise in crystalline silicon at 123K. This will guide the design of suspensions in planned future cryogenic ground-based gravitational-wave detectors such as LIGO Voyager and the Einstein Telescope. This facility is also suitable for the testing of new mirror coatings at cryogenic temperatures.
title Low-vibration cryogenic test facility for next generation of ground-based gravitational-wave observatories
topic Instrumentation and Detectors
url https://arxiv.org/abs/2408.10477