Numerical simulation of autoresonant ions oscillations in an anharmonic electrostatic trap

Fuente: arXiv
Guardado en:
Detalles Bibliográficos
Autores principales: López, J. E., Paez-González, C. J., Hernández, A., Orozco, E. A., Tsygankov, P., Parada-Becerra, F. F.
Formato: Preprint
Publicado: 2024
Materias:
Acceso en línea:
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
_version_ 1866910572081053696
author López, J. E.
Paez-González, C. J.
Hernández, A.
Orozco, E. A.
Tsygankov, P.
Parada-Becerra, F. F.
author_facet López, J. E.
Paez-González, C. J.
Hernández, A.
Orozco, E. A.
Tsygankov, P.
Parada-Becerra, F. F.
contents This work presents the results of modelling the ion dynamics in the ART-MS (Autoresonant Trap Mass Spectrometry) device in the quasi-static approximation. This instrument utilizes an anharmonic, purely electrostatic trap for ion confinement and a radio frequency (RF) voltage source with decrementally varying frequency for selective ion extraction. The autoresonant interaction between the oscillatory motion of the ion and the RF voltage causes an increase in the amplitude of certain confined ions, allowing their selective extraction. Numerical modelling shows that the extraction of ions with a given mass occurs not only at the fundamental frequency but also at its harmonics. This effect reduces the selective properties of devices of this type because along with the main mass component for a given frequency, it is possible to enter the detector channel of ions with another mass, for which this frequency corresponds to the second or higher harmonics, even a superposition of some of these harmonics of different ions.
format Preprint
id arxiv_https___arxiv_org_abs_2408_11722
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle Numerical simulation of autoresonant ions oscillations in an anharmonic electrostatic trap
López, J. E.
Paez-González, C. J.
Hernández, A.
Orozco, E. A.
Tsygankov, P.
Parada-Becerra, F. F.
Applied Physics
Computational Physics
Instrumentation and Detectors
This work presents the results of modelling the ion dynamics in the ART-MS (Autoresonant Trap Mass Spectrometry) device in the quasi-static approximation. This instrument utilizes an anharmonic, purely electrostatic trap for ion confinement and a radio frequency (RF) voltage source with decrementally varying frequency for selective ion extraction. The autoresonant interaction between the oscillatory motion of the ion and the RF voltage causes an increase in the amplitude of certain confined ions, allowing their selective extraction. Numerical modelling shows that the extraction of ions with a given mass occurs not only at the fundamental frequency but also at its harmonics. This effect reduces the selective properties of devices of this type because along with the main mass component for a given frequency, it is possible to enter the detector channel of ions with another mass, for which this frequency corresponds to the second or higher harmonics, even a superposition of some of these harmonics of different ions.
title Numerical simulation of autoresonant ions oscillations in an anharmonic electrostatic trap
topic Applied Physics
Computational Physics
Instrumentation and Detectors
url https://arxiv.org/abs/2408.11722