MBSS-T1: Model-Based Subject-Specific Self-Supervised Motion Correction for Robust Cardiac T1 Mapping

Fuente: arXiv
Saved in:
Bibliographic Details
Main Authors: Hanania, Eyal, Zehavi-Lenz, Adi, Volovik, Ilya, Link-Sourani, Daphna, Cohen, Israel, Freiman, Moti
Format: Preprint
Published: 2024
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866917947240349696
author Hanania, Eyal
Zehavi-Lenz, Adi
Volovik, Ilya
Link-Sourani, Daphna
Cohen, Israel
Freiman, Moti
author_facet Hanania, Eyal
Zehavi-Lenz, Adi
Volovik, Ilya
Link-Sourani, Daphna
Cohen, Israel
Freiman, Moti
contents Cardiac T1 mapping is a valuable quantitative MRI technique for diagnosing diffuse myocardial diseases. Traditional methods, relying on breath-hold sequences and cardiac triggering based on an ECG signal, face challenges with patient compliance, limiting their effectiveness. Image registration can enable motion-robust cardiac T1 mapping, but inherent intensity differences between time points pose a challenge. We present MBSS-T1, a subject-specific self-supervised model for motion correction in cardiac T1 mapping. Physical constraints, implemented through a loss function comparing synthesized and motion-corrected images, enforce signal decay behavior, while anatomical constraints, applied via a Dice loss, ensure realistic deformations. The unique combination of these constraints results in motion-robust cardiac T1 mapping along the longitudinal relaxation axis. In a 5-fold experiment on a public dataset of 210 patients (STONE sequence) and an internal dataset of 19 patients (MOLLI sequence), MBSS-T1 outperformed baseline deep-learning registration methods. It achieved superior model fitting quality ($R^2$: 0.975 vs. 0.941, 0.946 for STONE; 0.987 vs. 0.982, 0.965 for MOLLI free-breathing; 0.994 vs. 0.993, 0.991 for MOLLI breath-hold), anatomical alignment (Dice: 0.89 vs. 0.84, 0.88 for STONE; 0.963 vs. 0.919, 0.851 for MOLLI free-breathing; 0.954 vs. 0.924, 0.871 for MOLLI breath-hold), and visual quality (4.33 vs. 3.38, 3.66 for STONE; 4.1 vs. 3.5, 3.28 for MOLLI free-breathing; 3.79 vs. 3.15, 2.84 for MOLLI breath-hold). MBSS-T1 enables motion-robust T1 mapping for broader patient populations, overcoming challenges such as suboptimal compliance, and facilitates free-breathing cardiac T1 mapping without requiring large annotated datasets. Our code is available at https://github.com/TechnionComputationalMRILab/MBSS-T1.
format Preprint
id arxiv_https___arxiv_org_abs_2408_11992
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle MBSS-T1: Model-Based Subject-Specific Self-Supervised Motion Correction for Robust Cardiac T1 Mapping
Hanania, Eyal
Zehavi-Lenz, Adi
Volovik, Ilya
Link-Sourani, Daphna
Cohen, Israel
Freiman, Moti
Image and Video Processing
Computer Vision and Pattern Recognition
Cardiac T1 mapping is a valuable quantitative MRI technique for diagnosing diffuse myocardial diseases. Traditional methods, relying on breath-hold sequences and cardiac triggering based on an ECG signal, face challenges with patient compliance, limiting their effectiveness. Image registration can enable motion-robust cardiac T1 mapping, but inherent intensity differences between time points pose a challenge. We present MBSS-T1, a subject-specific self-supervised model for motion correction in cardiac T1 mapping. Physical constraints, implemented through a loss function comparing synthesized and motion-corrected images, enforce signal decay behavior, while anatomical constraints, applied via a Dice loss, ensure realistic deformations. The unique combination of these constraints results in motion-robust cardiac T1 mapping along the longitudinal relaxation axis. In a 5-fold experiment on a public dataset of 210 patients (STONE sequence) and an internal dataset of 19 patients (MOLLI sequence), MBSS-T1 outperformed baseline deep-learning registration methods. It achieved superior model fitting quality ($R^2$: 0.975 vs. 0.941, 0.946 for STONE; 0.987 vs. 0.982, 0.965 for MOLLI free-breathing; 0.994 vs. 0.993, 0.991 for MOLLI breath-hold), anatomical alignment (Dice: 0.89 vs. 0.84, 0.88 for STONE; 0.963 vs. 0.919, 0.851 for MOLLI free-breathing; 0.954 vs. 0.924, 0.871 for MOLLI breath-hold), and visual quality (4.33 vs. 3.38, 3.66 for STONE; 4.1 vs. 3.5, 3.28 for MOLLI free-breathing; 3.79 vs. 3.15, 2.84 for MOLLI breath-hold). MBSS-T1 enables motion-robust T1 mapping for broader patient populations, overcoming challenges such as suboptimal compliance, and facilitates free-breathing cardiac T1 mapping without requiring large annotated datasets. Our code is available at https://github.com/TechnionComputationalMRILab/MBSS-T1.
title MBSS-T1: Model-Based Subject-Specific Self-Supervised Motion Correction for Robust Cardiac T1 Mapping
topic Image and Video Processing
Computer Vision and Pattern Recognition
url https://arxiv.org/abs/2408.11992