Laboratory x-ray nano-computed tomography for biomedical research

Fuente: arXiv
Salvato in:
Dettagli Bibliografici
Autori principali: Dreier, Till, Krüger, Robin, Bernström, Gustaf, Tran-Lundmark, Karin, Gonçalves, Isabel, Bech, Martin
Natura: Preprint
Pubblicazione: 2024
Soggetti:
Accesso online:
Tags: Aggiungi Tag
Nessun Tag, puoi essere il primo ad aggiungerne!!
_version_ 1866929469767286784
author Dreier, Till
Krüger, Robin
Bernström, Gustaf
Tran-Lundmark, Karin
Gonçalves, Isabel
Bech, Martin
author_facet Dreier, Till
Krüger, Robin
Bernström, Gustaf
Tran-Lundmark, Karin
Gonçalves, Isabel
Bech, Martin
contents High-resolution x-ray tomography is a common technique for biomedical research using synchrotron sources. With advancements in laboratory x-ray sources, an increasing number of experiments can be performed in the lab. In this paper, the design, implementation, and verification of a laboratory setup for x-ray nano-computed tomography is presented using a nano-focus x-ray source and high geometric magnification not requiring any optical elements. Comparing a scintillator-based detector to a photon counting detector shows a clear benefit of using photon counting detectors for these applications, where the flux of the x-ray source is limited and samples have low contrast. Sample contrast is enhanced using propagation-based phase contrast. The resolution of the system is verified using 2D resolution charts and using Fourier Ring Correlation on reconstructed CT slices. Evaluating noise and contrast highlights the benefits of photon counting detectors and the contrast improvement through phase contrast. The implemented setup is capable of reaching sub-micron resolution and satisfying contrast in biological samples, like paraffin embedded tissue.
format Preprint
id arxiv_https___arxiv_org_abs_2408_12336
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle Laboratory x-ray nano-computed tomography for biomedical research
Dreier, Till
Krüger, Robin
Bernström, Gustaf
Tran-Lundmark, Karin
Gonçalves, Isabel
Bech, Martin
Instrumentation and Detectors
Medical Physics
High-resolution x-ray tomography is a common technique for biomedical research using synchrotron sources. With advancements in laboratory x-ray sources, an increasing number of experiments can be performed in the lab. In this paper, the design, implementation, and verification of a laboratory setup for x-ray nano-computed tomography is presented using a nano-focus x-ray source and high geometric magnification not requiring any optical elements. Comparing a scintillator-based detector to a photon counting detector shows a clear benefit of using photon counting detectors for these applications, where the flux of the x-ray source is limited and samples have low contrast. Sample contrast is enhanced using propagation-based phase contrast. The resolution of the system is verified using 2D resolution charts and using Fourier Ring Correlation on reconstructed CT slices. Evaluating noise and contrast highlights the benefits of photon counting detectors and the contrast improvement through phase contrast. The implemented setup is capable of reaching sub-micron resolution and satisfying contrast in biological samples, like paraffin embedded tissue.
title Laboratory x-ray nano-computed tomography for biomedical research
topic Instrumentation and Detectors
Medical Physics
url https://arxiv.org/abs/2408.12336