Thermal Management Design and Key Technology Validation for PandaX Underground Experiment

Fuente: arXiv
Saved in:
Bibliographic Details
Main Authors: Zhan, Tao, Liu, Jianglai, Liu, Yang, Wu, Weihao, Yan, Binbin, Wang, Zhou
Format: Preprint
Published: 2024
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866911001059786752
author Zhan, Tao
Liu, Jianglai
Liu, Yang
Wu, Weihao
Yan, Binbin
Wang, Zhou
author_facet Zhan, Tao
Liu, Jianglai
Liu, Yang
Wu, Weihao
Yan, Binbin
Wang, Zhou
contents The scale of liquid xenon experiments for rare events searching is expanding, which is planned even to fifty tons level. The detector and distillation tower require a reliable cooling source with large cooling power at liquid xenon temperature range. Pulse tube refrigerators and GM refrigerators, which were widely used in previous detectors, have the disadvantages of small cooling power, large space occupation, and non-standby mutuality, which become bottlenecks of the experiment scale expansion. In this study, an auto-cascade refrigerator with ethanol coolant is developed, and the heat transfer effect is improved by adopting the concentric shaft heat exchanger and after-pumping heat transfer scheme. The 2.5 kW stable cooling power is obtained at 155 K. Further, the feasibility and key technology of the centralized cooling system of 5 kw at 160 K is discussed. The study can simplify liquid xenon experimental auxiliary devices, which will be helpful for the PandaX-xT experiment scheme and its laboratory infrastructure design.
format Preprint
id arxiv_https___arxiv_org_abs_2408_13433
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle Thermal Management Design and Key Technology Validation for PandaX Underground Experiment
Zhan, Tao
Liu, Jianglai
Liu, Yang
Wu, Weihao
Yan, Binbin
Wang, Zhou
Instrumentation and Detectors
High Energy Physics - Experiment
The scale of liquid xenon experiments for rare events searching is expanding, which is planned even to fifty tons level. The detector and distillation tower require a reliable cooling source with large cooling power at liquid xenon temperature range. Pulse tube refrigerators and GM refrigerators, which were widely used in previous detectors, have the disadvantages of small cooling power, large space occupation, and non-standby mutuality, which become bottlenecks of the experiment scale expansion. In this study, an auto-cascade refrigerator with ethanol coolant is developed, and the heat transfer effect is improved by adopting the concentric shaft heat exchanger and after-pumping heat transfer scheme. The 2.5 kW stable cooling power is obtained at 155 K. Further, the feasibility and key technology of the centralized cooling system of 5 kw at 160 K is discussed. The study can simplify liquid xenon experimental auxiliary devices, which will be helpful for the PandaX-xT experiment scheme and its laboratory infrastructure design.
title Thermal Management Design and Key Technology Validation for PandaX Underground Experiment
topic Instrumentation and Detectors
High Energy Physics - Experiment
url https://arxiv.org/abs/2408.13433