3Dπ: Three-Dimensional Positron Imaging, A Novel Total-Body PET Scanner Using Xenon-Doped Liquid Argon Scintillator

Fuente: arXiv
Guardado en:
Detalles Bibliográficos
Autores principales: Zabihi, Azam, Li, Xinran, Ramirez, Alejandro, Rolo, Manuel D. Da Rocha, Franco, Davide, Gabriele, Federico, Galbiati, Cristiano, Lai, Michela, Marlow, Daniel R., Renshaw, Andrew, Westerdale, Shawn, Wada, Masayuki
Formato: Preprint
Publicado: 2024
Materias:
Acceso en línea:
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
_version_ 1866912002600861696
author Zabihi, Azam
Li, Xinran
Ramirez, Alejandro
Rolo, Manuel D. Da Rocha
Franco, Davide
Gabriele, Federico
Galbiati, Cristiano
Lai, Michela
Marlow, Daniel R.
Renshaw, Andrew
Westerdale, Shawn
Wada, Masayuki
author_facet Zabihi, Azam
Li, Xinran
Ramirez, Alejandro
Rolo, Manuel D. Da Rocha
Franco, Davide
Gabriele, Federico
Galbiati, Cristiano
Lai, Michela
Marlow, Daniel R.
Renshaw, Andrew
Westerdale, Shawn
Wada, Masayuki
contents Objective: This paper introduces a novel PET imaging methodology called 3-dimensional positron imaging (3Dπ), which integrates total-body (TB) coverage, time-of-flight (TOF) technology, ultra-low dose imaging capabilities, and ultra-fast readout electronics inspired by emerging technology from the DarkSide collaboration. Approach: The study evaluates the performance of 3Dπ using Monte Carlo simulations based on NEMA NU 2-2018 protocols. The methodology employs a homogenous, monolithic scintillator composed of liquid argon (LAr) doped with xenon (Xe) with silicon photomultipliers (SiPM) operating at cryogenic temperatures. Main results: Significant enhancements in system performance are observed, with the 3Dπ system achieving a noise equivalent count rate (NECR) of 3.2 Mcps which is approximately two times higher than uEXPLORER's peak NECR (1.5 Mcps) at 17.3 (kBq/mL). Spatial resolution measurements show an average FWHM of 2.7 mm across both axial positions. The system exhibits superior sensitivity, with values reaching 373 kcps/MBq with a line source at the center of the field of view. Additionally, 3Dπ achieves a TOF resolution of 151 ps at 5.3 kBq/mL, highlighting its potential to produce high-quality images with reduced noise levels. Significance: The study underscores the potential of 3Dπ in improving PET imaging performance, offering the potential for shorter scan times and reduced radiation exposure for patients. The Xe-doped LAr offers advantages such as fast scintillation, enhanced light yield, and cost-effectiveness. Future research will focus on optimizing system geometry and further refining reconstruction algorithms to exploit the strengths of 3Dπ for clinical applications.
format Preprint
id arxiv_https___arxiv_org_abs_2408_14645
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle 3Dπ: Three-Dimensional Positron Imaging, A Novel Total-Body PET Scanner Using Xenon-Doped Liquid Argon Scintillator
Zabihi, Azam
Li, Xinran
Ramirez, Alejandro
Rolo, Manuel D. Da Rocha
Franco, Davide
Gabriele, Federico
Galbiati, Cristiano
Lai, Michela
Marlow, Daniel R.
Renshaw, Andrew
Westerdale, Shawn
Wada, Masayuki
Medical Physics
Objective: This paper introduces a novel PET imaging methodology called 3-dimensional positron imaging (3Dπ), which integrates total-body (TB) coverage, time-of-flight (TOF) technology, ultra-low dose imaging capabilities, and ultra-fast readout electronics inspired by emerging technology from the DarkSide collaboration. Approach: The study evaluates the performance of 3Dπ using Monte Carlo simulations based on NEMA NU 2-2018 protocols. The methodology employs a homogenous, monolithic scintillator composed of liquid argon (LAr) doped with xenon (Xe) with silicon photomultipliers (SiPM) operating at cryogenic temperatures. Main results: Significant enhancements in system performance are observed, with the 3Dπ system achieving a noise equivalent count rate (NECR) of 3.2 Mcps which is approximately two times higher than uEXPLORER's peak NECR (1.5 Mcps) at 17.3 (kBq/mL). Spatial resolution measurements show an average FWHM of 2.7 mm across both axial positions. The system exhibits superior sensitivity, with values reaching 373 kcps/MBq with a line source at the center of the field of view. Additionally, 3Dπ achieves a TOF resolution of 151 ps at 5.3 kBq/mL, highlighting its potential to produce high-quality images with reduced noise levels. Significance: The study underscores the potential of 3Dπ in improving PET imaging performance, offering the potential for shorter scan times and reduced radiation exposure for patients. The Xe-doped LAr offers advantages such as fast scintillation, enhanced light yield, and cost-effectiveness. Future research will focus on optimizing system geometry and further refining reconstruction algorithms to exploit the strengths of 3Dπ for clinical applications.
title 3Dπ: Three-Dimensional Positron Imaging, A Novel Total-Body PET Scanner Using Xenon-Doped Liquid Argon Scintillator
topic Medical Physics
url https://arxiv.org/abs/2408.14645