contents Detecting mid-infrared (MIR) radiation has significant astronomical applications, although limited by unsatisfactory MIR detectors. Here we reported on the realization of a MIR up-conversion interferometer based on synthetic long base-line (SLBL) in the laboratory. The experimental system consisted of an interferometer and subsequent up-conversion detection part of mid-infrared signal, which streamlined the structure and enhanced the reliability of the system. By using a tungsten filament lamp as an imitated star, we not only achieved the single target angle resolution of 1.10 times 10^(-4) rad, but also obtained the field angle resolution of 3.0 times 10^(-4) rad of double star targets. The angular resolution is in inverse proportion to the length of baseline. The maximum length of simulated baseline in the laboratory is about 3cm. In a Keck Interferometer (KI) liked program, the base line can reach up to 85m leading to a corresponding angular resolution of 3.0 times 10^(-9) rad (about 1.8mas). The study will offer potential benefits in extending the usage of mid-infrared light in astronomical exploration.
format Preprint
id arxiv_https___arxiv_org_abs_2408_14902
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle In-Lab High Resolution Mid-infrared Up-conversion Stellar Interferometer Based on Synthetic Long Base-Line
Han, Zhao-Qi-Zhi
Ge, Zheng
Luo, Wen-Tao
Cai, Yi-Fu
Wang, Xiao-Hua
Chen, Li
Li, Wu-Zhen
Zhou, Zhi-Yuan
Shi, Bao-Sen
Instrumentation and Methods for Astrophysics
Applied Physics
Optics
Detecting mid-infrared (MIR) radiation has significant astronomical applications, although limited by unsatisfactory MIR detectors. Here we reported on the realization of a MIR up-conversion interferometer based on synthetic long base-line (SLBL) in the laboratory. The experimental system consisted of an interferometer and subsequent up-conversion detection part of mid-infrared signal, which streamlined the structure and enhanced the reliability of the system. By using a tungsten filament lamp as an imitated star, we not only achieved the single target angle resolution of 1.10 times 10^(-4) rad, but also obtained the field angle resolution of 3.0 times 10^(-4) rad of double star targets. The angular resolution is in inverse proportion to the length of baseline. The maximum length of simulated baseline in the laboratory is about 3cm. In a Keck Interferometer (KI) liked program, the base line can reach up to 85m leading to a corresponding angular resolution of 3.0 times 10^(-9) rad (about 1.8mas). The study will offer potential benefits in extending the usage of mid-infrared light in astronomical exploration.
title In-Lab High Resolution Mid-infrared Up-conversion Stellar Interferometer Based on Synthetic Long Base-Line
topic Instrumentation and Methods for Astrophysics
Applied Physics
Optics
url https://arxiv.org/abs/2408.14902