Validation of Thin-foil proton recoil neutron spectrometer prototype for application in high yield DT fusion devices

Fuente: arXiv
Salvato in:
Dettagli Bibliografici
Autori principali: Marcinkevicius, B., Sunden, E. Andersson, Ericsson, G., Hjalmarsson, A.
Natura: Preprint
Pubblicazione: 2024
Soggetti:
Accesso online:
Tags: Aggiungi Tag
Nessun Tag, puoi essere il primo ad aggiungerne!!
_version_ 1866913486142963712
author Marcinkevicius, B.
Sunden, E. Andersson
Ericsson, G.
Hjalmarsson, A.
author_facet Marcinkevicius, B.
Sunden, E. Andersson
Ericsson, G.
Hjalmarsson, A.
contents The use of Thin-foil Proton Recoil (TPR) spectrometers for application in neutron spectroscopy is of high relevance for future fusion devices such as ITER, where neutron spectroscopy will play a crucial role in fuel content monitoring. Existing research based on simulations of the performance of TPR spectrometers at ITER has demonstrated positive results. However, experimental validation of the simulations would greatly benefit the reliability of conclusions. In this study, we designed and constructed a prototype TPR neutron spectrometer and employed a DT neutron generator as a neutron source to perform measurements. We compared the experimental results with the simulation results using the Geant4 model of the experiment. The simulation and experimental results match within silicon detector intrinsic energy resolution. This approach ensures the experimental validation of the Geant4 based simulations of the TPR spectrometer. The experimental results demonstrated the feasibility of utilizing nuclear reactions measured in silicon detectors, specifically $^{28}$Si(n,d) and $^{28}$Si(n,$α$), for energy calibration purposes. A comparison of the experiment and the simulation shows that the mean peak energy and full width at half maximum are within 150 keV. The calculated detector efficiency underestimates the experimentally determined efficiency up to 33\%. Discrepancies in the measured energy spectrum indicate the need for a more refined model and experiment control. Overall, the successful validation of the developed Geant4 simulation model against the experimentally measured energy spectra increases confidence in the applicability of such simulation results in other devices. The demonstrated energy calibration highlights new possibilities for neutron spectrometer monitoring during operation at ITER.
format Preprint
id arxiv_https___arxiv_org_abs_2408_16093
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle Validation of Thin-foil proton recoil neutron spectrometer prototype for application in high yield DT fusion devices
Marcinkevicius, B.
Sunden, E. Andersson
Ericsson, G.
Hjalmarsson, A.
Instrumentation and Detectors
Plasma Physics
The use of Thin-foil Proton Recoil (TPR) spectrometers for application in neutron spectroscopy is of high relevance for future fusion devices such as ITER, where neutron spectroscopy will play a crucial role in fuel content monitoring. Existing research based on simulations of the performance of TPR spectrometers at ITER has demonstrated positive results. However, experimental validation of the simulations would greatly benefit the reliability of conclusions. In this study, we designed and constructed a prototype TPR neutron spectrometer and employed a DT neutron generator as a neutron source to perform measurements. We compared the experimental results with the simulation results using the Geant4 model of the experiment. The simulation and experimental results match within silicon detector intrinsic energy resolution. This approach ensures the experimental validation of the Geant4 based simulations of the TPR spectrometer. The experimental results demonstrated the feasibility of utilizing nuclear reactions measured in silicon detectors, specifically $^{28}$Si(n,d) and $^{28}$Si(n,$α$), for energy calibration purposes. A comparison of the experiment and the simulation shows that the mean peak energy and full width at half maximum are within 150 keV. The calculated detector efficiency underestimates the experimentally determined efficiency up to 33\%. Discrepancies in the measured energy spectrum indicate the need for a more refined model and experiment control. Overall, the successful validation of the developed Geant4 simulation model against the experimentally measured energy spectra increases confidence in the applicability of such simulation results in other devices. The demonstrated energy calibration highlights new possibilities for neutron spectrometer monitoring during operation at ITER.
title Validation of Thin-foil proton recoil neutron spectrometer prototype for application in high yield DT fusion devices
topic Instrumentation and Detectors
Plasma Physics
url https://arxiv.org/abs/2408.16093