Infrared thermal imaging camera to measure low temperature thermal fields

Fuente: arXiv
Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Gordiyenko, E., Fomenko, Yu., Shustakova, G., Kovalov, G., Shevchenko, S.
Format: Preprint
Veröffentlicht: 2024
Schlagworte:
Online-Zugang:
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
_version_ 1866929478273335296
author Gordiyenko, E.
Fomenko, Yu.
Shustakova, G.
Kovalov, G.
Shevchenko, S.
author_facet Gordiyenko, E.
Fomenko, Yu.
Shustakova, G.
Kovalov, G.
Shevchenko, S.
contents To measure low-temperature thermal fields, we have developed a single-element cooled thermal imaging camera for a spectral range of 8÷14 μm with an internal shutter for radiometric calibration. To improve the accuracy of measuring the temperature of cold objects, we used a shutter with a combined emissivity as an internal reference source of radiation at the input of the device optical unit. With this aim a small mirror was fixed in the center on its surface covered black, thereby ensuring an efficient reflection of radiation in a wide spectral range of wavelengths. When processing the signal for each pixel of the thermal image, the differential value of the detector response to the shutter blackened and mirror areas was used as a reference. A relative measurement error of 3 percent was obtained for the studied objects with a temperature of -150 °C. The device was successfully used for remote study of thermal field dynamics during freeze-thawing of biological tissues in vivo.
format Preprint
id arxiv_https___arxiv_org_abs_2408_16165
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle Infrared thermal imaging camera to measure low temperature thermal fields
Gordiyenko, E.
Fomenko, Yu.
Shustakova, G.
Kovalov, G.
Shevchenko, S.
Instrumentation and Detectors
Applied Physics
To measure low-temperature thermal fields, we have developed a single-element cooled thermal imaging camera for a spectral range of 8÷14 μm with an internal shutter for radiometric calibration. To improve the accuracy of measuring the temperature of cold objects, we used a shutter with a combined emissivity as an internal reference source of radiation at the input of the device optical unit. With this aim a small mirror was fixed in the center on its surface covered black, thereby ensuring an efficient reflection of radiation in a wide spectral range of wavelengths. When processing the signal for each pixel of the thermal image, the differential value of the detector response to the shutter blackened and mirror areas was used as a reference. A relative measurement error of 3 percent was obtained for the studied objects with a temperature of -150 °C. The device was successfully used for remote study of thermal field dynamics during freeze-thawing of biological tissues in vivo.
title Infrared thermal imaging camera to measure low temperature thermal fields
topic Instrumentation and Detectors
Applied Physics
url https://arxiv.org/abs/2408.16165