An Optimized Binning and Probabilistic Slice Sharing Algorithm for Motion Correction in Abdominal DW-MRI

Fuente: arXiv
Saved in:
Bibliographic Details
Main Authors: Su, Michelle, Ariyurek, Cemre, Vasylechko, Serge, Afacan, Onur, Kurugol, Sila
Format: Preprint
Published: 2024
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866909393270865920
author Su, Michelle
Ariyurek, Cemre
Vasylechko, Serge
Afacan, Onur
Kurugol, Sila
author_facet Su, Michelle
Ariyurek, Cemre
Vasylechko, Serge
Afacan, Onur
Kurugol, Sila
contents Diffusion-weighted magnetic resonance imaging (DW-MRI) is a powerful, non-invasive tool for detecting and characterizing abdominal lesions to facilitate early diagnosis, but respiratory motion during a scan reduces image quality and accuracy of quantitative biomarkers. Respiratory binning, which groups image slices into motion phase bins based on a navigator signal, can help mitigate motion artifacts. However, in DW-MRI, the standard binning technique often generates volumes with missing slices along the superior-inferior axis. Thus, longer scans are required to obtain volumes without gaps. In this study, we proposed a new binning technique to minimize missing slices without increasing scan time. We first designed an algorithm using dynamic programming and prefix sum approaches to optimize the initial binning of MR images. Then, we developed a probabilistic refinement phase, selecting some slices to belong in two neighboring bins to further reduce missing slices. We tested our two-phase technique on free-breathing abdominal DW-MRI scans from eight subjects, including one with tumors. The proposed technique significantly reduced missing slices compared to standard binning (p<1.0*10-15), yielding an average reduction of 81.74+/-7.58%. Our technique also reduced motion artifacts, improving the conspicuity of malignant lesions. Apparent Diffusion Coefficient (ADC) maps generated from free-breathing scans corrected using the proposed technique had lower intra-subject variability compared to ADC maps from uncorrected free-breathing and shallow-breathing scans (p<0.001). Additionally, ADC maps from shallow-breathing scans were more consistent with corrected free-breathing maps rather than uncorrected free-breathing maps (p<0.01). The proposed technique corrects for motion while simultaneously reducing missing slices, allowing for shorter acquisition times compared to standard binning.
format Preprint
id arxiv_https___arxiv_org_abs_2409_00798
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle An Optimized Binning and Probabilistic Slice Sharing Algorithm for Motion Correction in Abdominal DW-MRI
Su, Michelle
Ariyurek, Cemre
Vasylechko, Serge
Afacan, Onur
Kurugol, Sila
Image and Video Processing
Signal Processing
Diffusion-weighted magnetic resonance imaging (DW-MRI) is a powerful, non-invasive tool for detecting and characterizing abdominal lesions to facilitate early diagnosis, but respiratory motion during a scan reduces image quality and accuracy of quantitative biomarkers. Respiratory binning, which groups image slices into motion phase bins based on a navigator signal, can help mitigate motion artifacts. However, in DW-MRI, the standard binning technique often generates volumes with missing slices along the superior-inferior axis. Thus, longer scans are required to obtain volumes without gaps. In this study, we proposed a new binning technique to minimize missing slices without increasing scan time. We first designed an algorithm using dynamic programming and prefix sum approaches to optimize the initial binning of MR images. Then, we developed a probabilistic refinement phase, selecting some slices to belong in two neighboring bins to further reduce missing slices. We tested our two-phase technique on free-breathing abdominal DW-MRI scans from eight subjects, including one with tumors. The proposed technique significantly reduced missing slices compared to standard binning (p<1.0*10-15), yielding an average reduction of 81.74+/-7.58%. Our technique also reduced motion artifacts, improving the conspicuity of malignant lesions. Apparent Diffusion Coefficient (ADC) maps generated from free-breathing scans corrected using the proposed technique had lower intra-subject variability compared to ADC maps from uncorrected free-breathing and shallow-breathing scans (p<0.001). Additionally, ADC maps from shallow-breathing scans were more consistent with corrected free-breathing maps rather than uncorrected free-breathing maps (p<0.01). The proposed technique corrects for motion while simultaneously reducing missing slices, allowing for shorter acquisition times compared to standard binning.
title An Optimized Binning and Probabilistic Slice Sharing Algorithm for Motion Correction in Abdominal DW-MRI
topic Image and Video Processing
Signal Processing
url https://arxiv.org/abs/2409.00798