contents The intensity spectra recovered from the spectroscopic photographic plates were compared with the CCD spectra, and we found the difference between the two was 2.5%.The measurements were taken using a commercial flatbed scanner instead of a microdensitometer. The results indicate that the following two statements are inaccurate: (1) Correct measurement of spectroscopic plates requires a microdensitometer, and a commercial flatbed scanner is insufficient; (2) The spectrophotometric accuracy of spectroscopic plate is approximately 10% accurate. These results will encourage the creation and publication of a digital archive of spectroscopic plates. This paper presents the measurement of spectroscopic plates, the method of recovering intensity spectra from photographic density spectra, the results of comparison with CCD spectra, and discusses the causes of the high accuracy spectra obtained with a commercial flatbed scanner.
format Preprint
id arxiv_https___arxiv_org_abs_2409_01629
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle Spectrophotometric accuracy of spectra obtained from spectroscopic plates measured with a commercial flatbed scanner
Yanagisawa, Kenshi
Furusho, Reiko
Nemoto, Shiomi
Kasuga, Toshihiro
Iwashita, Yumi
Watanabe, Jun-ichi
Instrumentation and Methods for Astrophysics
The intensity spectra recovered from the spectroscopic photographic plates were compared with the CCD spectra, and we found the difference between the two was 2.5%.The measurements were taken using a commercial flatbed scanner instead of a microdensitometer. The results indicate that the following two statements are inaccurate: (1) Correct measurement of spectroscopic plates requires a microdensitometer, and a commercial flatbed scanner is insufficient; (2) The spectrophotometric accuracy of spectroscopic plate is approximately 10% accurate. These results will encourage the creation and publication of a digital archive of spectroscopic plates. This paper presents the measurement of spectroscopic plates, the method of recovering intensity spectra from photographic density spectra, the results of comparison with CCD spectra, and discusses the causes of the high accuracy spectra obtained with a commercial flatbed scanner.
title Spectrophotometric accuracy of spectra obtained from spectroscopic plates measured with a commercial flatbed scanner
topic Instrumentation and Methods for Astrophysics
url https://arxiv.org/abs/2409.01629